Transapical Closure of Re-entry Tear in Aortic Dissection With the Off-Label Use of a Gore Cardioform Septal Occluder Using 3D-Printed Simulation

We report a novel transapical approach to treat a challenging residual aortic dissection following prior type A dissection repair.Because of the complex anatomy and high surgical risk, a multidisciplinary team opted for a transapical transcatheter closure of the re-entry tear using a Gore Cardioform Septal Occluder.A custom 3D-printed model of the patient's aorta was used to simulate the device deployment.The procedure resulted in the successful exclusion of the false lumen and stabilization of the aneurysm, demonstrating the potential of this alternative technique in managing complex aortic dissections when conventional treatments are judged at too high risk.

Authors

Institutions

Publication Details

Journal
CJC Open
Published
2025-04-20
DOI
https://doi.org/10.1016/j.cjco.2025.04.010
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transapical Closure of Re-entry Tear in Aortic Dissection With the Off-Label Use of a Gore Cardioform Septal Occluder Using 3D-Printed Simulation

Stéphane Noble, Jean‐Paul Vallée, Mustafa Cikirikcioglu, Christoph Ellenberger et al.
CJC Open
Aortic Disease and Treatment Approaches
article

Transapical Closure of Re-entry Tear in Aortic Dissection With the Off-Label Use of a Gore Cardioform Septal Occluder Using 3D-Printed Simulation

Stéphane Noble, Jean‐Paul Vallée, Mustafa Cikirikcioglu, Christoph Ellenberger, Christoph Huber, H Müller, Louis Vaisière
article en

Abstract

We report a novel transapical approach to treat a challenging residual aortic dissection following prior type A dissection repair.Because of the complex anatomy and high surgical risk, a multidisciplinary team opted for a transapical transcatheter closure of the re-entry tear using a Gore Cardioform Septal Occluder.A custom 3D-printed model of the patient's aorta was used to simulate the device deployment.The procedure resulted in the successful exclusion of the false lumen and stabilization of the aneurysm, demonstrating the potential of this alternative technique in managing complex aortic dissections when conventional treatments are judged at too high risk.

CJC OpenVol. 7(7)
University Hospital of Geneva (CH)
Zero hunger
Openalex Percentile: Top 87%
Aortic Disease and Treatment Approaches
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.