Sensitivity analysis of fluorescent nuclear track detectors for fast and high‐energy mono‐energetic neutron dosimetry

This study compares FNTD and PADC detector sensitivities, demonstrating a notable energy and converter thickness dependence for FNTDs, which is essential for precise dosimetry. Accurate <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:msup><mml:mi>H</mml:mi> <mml:mo>∗</mml:mo></mml:msup> <mml:annotation>$H^{*}$</mml:annotation></mml:semantics> </mml:math> (10) values for fast mono-energetic neutrons up to <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:mrow><mml:mn>19</mml:mn> <mml:mspace></mml:mspace> <mml:mi>MeV</mml:mi></mml:mrow> <mml:annotation>$19 \,\mathrm{MeV}$</mml:annotation></mml:semantics> </mml:math> were determined utilizing MC simulations. A benchmarked MC model for fast neutrons was then applied to analyze the FNTD signal for high-energy neutrons.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2025-04-20
DOI
https://doi.org/10.1002/mp.17799
Citations
4
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
6.07

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensitivity analysis of fluorescent nuclear track detectors for fast and high‐energy mono‐energetic neutron dosimetry

Jeppe Brage Christensen, E.G. Yukihara, Alberto Stabilini, Stefan W. Schmidt et al.
4 citations
Medical Physics
Radiation Therapy and Dosimetry
6.07
article

Sensitivity analysis of fluorescent nuclear track detectors for fast and high‐energy mono‐energetic neutron dosimetry

Jeppe Brage Christensen, E.G. Yukihara, Alberto Stabilini, Stefan W. Schmidt, José Vedelago, B. Lutz
article en
4 citations

Abstract

This study compares FNTD and PADC detector sensitivities, demonstrating a notable energy and converter thickness dependence for FNTDs, which is essential for precise dosimetry. Accurate <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:msup><mml:mi>H</mml:mi> <mml:mo>∗</mml:mo></mml:msup> <mml:annotation>$H^{*}$</mml:annotation></mml:semantics> </mml:math> (10) values for fast mono-energetic neutrons up to <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:mrow><mml:mn>19</mml:mn> <mml:mspace></mml:mspace> <mml:mi>MeV</mml:mi></mml:mrow> <mml:annotation>$19 \,\mathrm{MeV}$</mml:annotation></mml:semantics> </mml:math> were determined utilizing MC simulations. A benchmarked MC model for fast neutrons was then applied to analyze the FNTD signal for high-energy neutrons.

Medical PhysicsVol. 52(7)
Physikalisch-Technische Bundesanstalt (DE), German Cancer Research Center (DE), Heidelberg University (DE), University Hospital Heidelberg (DE), Paul Scherrer Institute (CH)
Deutsche Forschungsgemeinschaft
Affordable and clean energy
Openalex Percentile: Top 4%
Radiation Therapy and Dosimetry
6.07
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Sensitivity analysis of fluorescent nuclear track detectors for fast and high‐energy mono‐energetic neutron dosimetry — Jeppe Brage Christensen, E.G. Yukihara, et al. · Medical Physics (2025) | TGRS Research Map | TGRS