Label-Free Electrochemical Cell-Based Biosensor for Toxicity Assay of Water-Soluble Form of Phosphatidylcholine

<b>Background/Objectives:</b> Our study brings a new method to properly evaluating drug efficacy at the non-invasive in vitro level. <b>Methods:</b> In this work, the electrochemical mediator-free and reagent-free analysis of cell lines based on the registration of electrochemical profiles of membrane proteins was developed. We studied the specificity of cell lines Wi-38 and HepG2 and the toxic effects of drugs on cell-on-electrode systems. <b>Results:</b> A linear dependence of the peak current on the concentration of cells applied to the electrode in the range from 1 × 10<sup>5</sup> to 6 × 10<sup>5</sup> cells/electrode was registered (R<sup>2</sup> 0.932 for Wi-38 and R<sup>2</sup> 0.912 for HepG2). The water-soluble form of phosphatidylcholine (wPC) nanoparticles recommended for atherosclerosis treatment and prevention of cardiovascular diseases did not show a toxic effect on the human fibroblast cells, Wi-38, or the human hepatocellular carcinoma cells, HepG2, at sufficiently high concentrations (such as 0.1-1 mg/mL). The antitumor drug doxorubicin, at concentrations of 3 and 10 μg/mL, showed a pronounced toxic effect on the tested cell lines, where the percentage of living cells was 50-55%. <b>Conclusions:</b> A comparative analysis of the cytotoxicity of wPC (0.1-1 mg/mL) and doxorubicin (3-10 μg/mL) on the cell lines Wi-38 and HepG2 using the MTT test and electrochemical approach for the registration of cells showed their clear adequacy.

Authors

Institutions

Publication Details

Journal
Biomedicines
Published
2025-04-20
DOI
https://doi.org/10.3390/biomedicines13040996
Citations
2
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
1.46

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Label-Free Electrochemical Cell-Based Biosensor for Toxicity Assay of Water-Soluble Form of Phosphatidylcholine

С. В. Иванов, Victoria V. Shumyantseva, L.V. Kostryukova, Alexander I. Archakov et al.
2 citations
Biomedicines
Electrochemical sensors and biosensors
1.46
article

Label-Free Electrochemical Cell-Based Biosensor for Toxicity Assay of Water-Soluble Form of Phosphatidylcholine

С. В. Иванов, Victoria V. Shumyantseva, L.V. Kostryukova, Alexander I. Archakov, Veronica V. Pronina, Elena G. Tichonova
article en
2 citations

Abstract

<b>Background/Objectives:</b> Our study brings a new method to properly evaluating drug efficacy at the non-invasive in vitro level. <b>Methods:</b> In this work, the electrochemical mediator-free and reagent-free analysis of cell lines based on the registration of electrochemical profiles of membrane proteins was developed. We studied the specificity of cell lines Wi-38 and HepG2 and the toxic effects of drugs on cell-on-electrode systems. <b>Results:</b> A linear dependence of the peak current on the concentration of cells applied to the electrode in the range from 1 × 10<sup>5</sup> to 6 × 10<sup>5</sup> cells/electrode was registered (R<sup>2</sup> 0.932 for Wi-38 and R<sup>2</sup> 0.912 for HepG2). The water-soluble form of phosphatidylcholine (wPC) nanoparticles recommended for atherosclerosis treatment and prevention of cardiovascular diseases did not show a toxic effect on the human fibroblast cells, Wi-38, or the human hepatocellular carcinoma cells, HepG2, at sufficiently high concentrations (such as 0.1-1 mg/mL). The antitumor drug doxorubicin, at concentrations of 3 and 10 μg/mL, showed a pronounced toxic effect on the tested cell lines, where the percentage of living cells was 50-55%. <b>Conclusions:</b> A comparative analysis of the cytotoxicity of wPC (0.1-1 mg/mL) and doxorubicin (3-10 μg/mL) on the cell lines Wi-38 and HepG2 using the MTT test and electrochemical approach for the registration of cells showed their clear adequacy.

BiomedicinesVol. 13(4)
Pirogov Russian National Research Medical University (RU), Institute of Biomedical Chemistry (RU)
Ministry of Science and Higher Education of the Russian Federation
Clean water and sanitation
Openalex Percentile: Top 18%
Electrochemical sensors and biosensors
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.