CMOS-Based Implantable Multi-Ion Image Sensor for Mg2+ Measurement in the Brain

An implantable multi-ion image sensor equipped with magnesium ion (Mg<sup>2+</sup>)-and calcium ion (Ca<sup>2+</sup>)-sensitive membranes was fabricated for the selective measurement of extracellular Mg<sup>2+</sup> in the brain, and the sensor performance was evaluated. This sensor complements the low selectivity of the Mg<sup>2+</sup>-sensitive membrane for Ca<sup>2+</sup> by depositing a Ca<sup>2+</sup>-sensitive membrane in addition to the Mg<sup>2+</sup>-sensitive membrane on a CMOS (Complementary Metal Oxide Semiconductor)-based potentiometric sensor array with 5.65 × 4.39 µm<sup>2</sup> pitch, enabling selective measurement of Mg<sup>2+</sup> and Ca<sup>2+</sup>. Characterization of the sensor confirmed a Ca<sup>2+</sup> sensitivity of 26.5 mV/dec and Mg<sup>2+</sup> sensitivity of 19 mV/dec. Based on validation experiments with varying concentrations of Mg<sup>2+</sup> and Ca<sup>2+</sup>, selective Ca<sup>2+</sup> and Mg<sup>2+</sup> measurements were successfully achieved. Furthermore, real-time imaging of Mg<sup>2+</sup> and Ca<sup>2+</sup> and quantification of their concentration changes were performed. The developed sensor may be successfully applied for extracellular multi-ion imaging of Mg<sup>2+</sup> and Ca<sup>2+</sup> in the living brain.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-04-20
DOI
https://doi.org/10.3390/s25082595
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CMOS-Based Implantable Multi-Ion Image Sensor for Mg2+ Measurement in the Brain

Kazuhiro Takahashi, Yasuyuki Kimura, Kazuaki Sawada, Hideo Doi et al.
Sensors
Analytical Chemistry and Sensors
article

CMOS-Based Implantable Multi-Ion Image Sensor for Mg2+ Measurement in the Brain

Kazuhiro Takahashi, Yasuyuki Kimura, Kazuaki Sawada, Hideo Doi, Toshihiko Noda, Tomoko Horio, Yuto Nakamura, Yong‐Joon Choi
article en

Abstract

An implantable multi-ion image sensor equipped with magnesium ion (Mg<sup>2+</sup>)-and calcium ion (Ca<sup>2+</sup>)-sensitive membranes was fabricated for the selective measurement of extracellular Mg<sup>2+</sup> in the brain, and the sensor performance was evaluated. This sensor complements the low selectivity of the Mg<sup>2+</sup>-sensitive membrane for Ca<sup>2+</sup> by depositing a Ca<sup>2+</sup>-sensitive membrane in addition to the Mg<sup>2+</sup>-sensitive membrane on a CMOS (Complementary Metal Oxide Semiconductor)-based potentiometric sensor array with 5.65 × 4.39 µm<sup>2</sup> pitch, enabling selective measurement of Mg<sup>2+</sup> and Ca<sup>2+</sup>. Characterization of the sensor confirmed a Ca<sup>2+</sup> sensitivity of 26.5 mV/dec and Mg<sup>2+</sup> sensitivity of 19 mV/dec. Based on validation experiments with varying concentrations of Mg<sup>2+</sup> and Ca<sup>2+</sup>, selective Ca<sup>2+</sup> and Mg<sup>2+</sup> measurements were successfully achieved. Furthermore, real-time imaging of Mg<sup>2+</sup> and Ca<sup>2+</sup> and quantification of their concentration changes were performed. The developed sensor may be successfully applied for extracellular multi-ion imaging of Mg<sup>2+</sup> and Ca<sup>2+</sup> in the living brain.

SensorsVol. 25(8)
Toyohashi University of Technology (JP)
Ministry of Education, Culture, Sports, Science and Technology, Japan Society for the Promotion of Science
Openalex Percentile: Top 89%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.