High Concordance of E-Nose-Derived Breathprints in a Healthy Population: A Cross-Sectional Observational Study

Exhaled breath analysis using electronic noses (e-noses) is a promising non-invasive diagnostic tool. However, a lack of standardized protocols limits clinical implementation. This study evaluates the consistency of breathprints in healthy subjects using the Cyranose 320 e-nose to support standardization efforts. Breath samples from 139 healthy non-smoking subjects (age range 18-65 years) were collected using a standardized protocol. Participants exhaled into a Tedlar bag for immediate analysis with the Cyranose 320. Principal Component Analysis (PCA) was used to reduce data dimensionality, and K-means clustering grouped subjects based on breathprints. PCA identified four principal components explaining 97.15% of variance. K-means clustering revealed two clusters: 1 outlier and 138 subjects with highly similar breathprints. The median distance from the cluster center was 0.21 (IQR: 0.18-0.24), indicating low variability. Box plots confirmed breathprint consistency across subjects. The high consistency of breathprints in healthy subjects supports the feasibility of standardizing e-nose protocols. These findings highlight the potential of e-noses for clinical diagnostics, warranting further research in diverse populations and disease cohorts.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-04-20
DOI
https://doi.org/10.3390/s25082610
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High Concordance of E-Nose-Derived Breathprints in a Healthy Population: A Cross-Sectional Observational Study

Andrea Portacci, Teresa Ranieri, Vitaliano Nicola Quaranta, Giovanna Elisiana Carpagnano et al.
Sensors
Advanced Chemical Sensor Technologies
article

High Concordance of E-Nose-Derived Breathprints in a Healthy Population: A Cross-Sectional Observational Study

Andrea Portacci, Teresa Ranieri, Vitaliano Nicola Quaranta, Giovanna Elisiana Carpagnano, Silvano Dragonieri
article en

Abstract

Exhaled breath analysis using electronic noses (e-noses) is a promising non-invasive diagnostic tool. However, a lack of standardized protocols limits clinical implementation. This study evaluates the consistency of breathprints in healthy subjects using the Cyranose 320 e-nose to support standardization efforts. Breath samples from 139 healthy non-smoking subjects (age range 18-65 years) were collected using a standardized protocol. Participants exhaled into a Tedlar bag for immediate analysis with the Cyranose 320. Principal Component Analysis (PCA) was used to reduce data dimensionality, and K-means clustering grouped subjects based on breathprints. PCA identified four principal components explaining 97.15% of variance. K-means clustering revealed two clusters: 1 outlier and 138 subjects with highly similar breathprints. The median distance from the cluster center was 0.21 (IQR: 0.18-0.24), indicating low variability. Box plots confirmed breathprint consistency across subjects. The high consistency of breathprints in healthy subjects supports the feasibility of standardizing e-nose protocols. These findings highlight the potential of e-noses for clinical diagnostics, warranting further research in diverse populations and disease cohorts.

SensorsVol. 25(8)
University of Bari Aldo Moro (IT)
Good health and well-being
Openalex Percentile: Top 93%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.