Explosives Analysis Using Thin-Layer Chromatography–Quantum Cascade Laser Spectroscopy

A new hyphenated technique using thin-layer chromatography (TLC) to separate analytes in mixtures, coupled with mid-infrared (MIR) laser spectroscopy for identification and quantification, is presented. The method, which provides a means for rapid screening of analytes that is practical, low-cost, fast, robust, and reproducible, was tested using nitroaromatic and aliphatic nitro high explosives (HEs) as target analytes. HEs are anthropogenic contaminants containing an -NO<sub>2</sub> group. For validation of the new technique, a direct comparison of the 2,4,6-trinitrotoluene (TNT) spectrum, obtained by attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopy coupled with TLC, was carried out. The MIR laser spectroscopy-based method was evaluated by calculating the analytical figures of merit regarding the calibration curves' linearity and the method's sensitivity and precision. The TNT spectrum obtained by the MIR laser method showed two prominent and characteristic bands of the explosive at approximately 1350 cm<sup>-1</sup> and 1550 cm<sup>-1</sup> compared to the spectrum acquired by ATR-FTIR. The detection limit calculated for TNT was 84 ng, while the quantification limit was 252 ng. Multivariate analysis was used to evaluate the spectroscopic data to identify sources of variation and determine their relation. Partial least squares (PLS) regression analysis and PLS combined with discriminant analysis (PLS-DA) were used for quantification and classification. The new technique, TLC-QCL, is amenable to a smaller footprint with further developments in MIR laser technology, making it portable for fieldwork.

Authors

Institutions

Publication Details

Journal
Molecules
Published
2025-04-19
DOI
https://doi.org/10.3390/molecules30081844
Citations
1
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.76

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Explosives Analysis Using Thin-Layer Chromatography–Quantum Cascade Laser Spectroscopy

Leonardo C. Pacheco‐Londoño, John R. Castro-Suárez, Samuel P. Hernández‐Rivera, Tamara Félix-Massa et al.
1 citations
Molecules
Mass Spectrometry Techniques and Applications
0.76
article

Explosives Analysis Using Thin-Layer Chromatography–Quantum Cascade Laser Spectroscopy

Leonardo C. Pacheco‐Londoño, John R. Castro-Suárez, Samuel P. Hernández‐Rivera, Tamara Félix-Massa, José A. Centeno, Luis Pérez-Almodóvar, José L. Ruiz‐Caballero, Doris M. Laguer-Martínez
article en
1 citations

Abstract

A new hyphenated technique using thin-layer chromatography (TLC) to separate analytes in mixtures, coupled with mid-infrared (MIR) laser spectroscopy for identification and quantification, is presented. The method, which provides a means for rapid screening of analytes that is practical, low-cost, fast, robust, and reproducible, was tested using nitroaromatic and aliphatic nitro high explosives (HEs) as target analytes. HEs are anthropogenic contaminants containing an -NO<sub>2</sub> group. For validation of the new technique, a direct comparison of the 2,4,6-trinitrotoluene (TNT) spectrum, obtained by attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopy coupled with TLC, was carried out. The MIR laser spectroscopy-based method was evaluated by calculating the analytical figures of merit regarding the calibration curves' linearity and the method's sensitivity and precision. The TNT spectrum obtained by the MIR laser method showed two prominent and characteristic bands of the explosive at approximately 1350 cm<sup>-1</sup> and 1550 cm<sup>-1</sup> compared to the spectrum acquired by ATR-FTIR. The detection limit calculated for TNT was 84 ng, while the quantification limit was 252 ng. Multivariate analysis was used to evaluate the spectroscopic data to identify sources of variation and determine their relation. Partial least squares (PLS) regression analysis and PLS combined with discriminant analysis (PLS-DA) were used for quantification and classification. The new technique, TLC-QCL, is amenable to a smaller footprint with further developments in MIR laser technology, making it portable for fieldwork.

MoleculesVol. 30(8)
Universidad del Sinú (CO), Universidad Simón Bolívar (CO), University of Puerto Rico-Mayaguez (PR)
U.S. Department of Homeland Security, Science and Technology Directorate
Openalex Percentile: Top 32%
Mass Spectrometry Techniques and Applications
0.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.