Dynamic response of soft tissue can be disregarded during femoral stem impaction

Common metal-on-metal mallet blows in surgery are very short and mostly excite high frequencies that are clearly above the natural frequency of the femur-tissue system. Those overcritical force impulses make the stem slide into the femur before the bone can even start moving. Hence, the individual mechanical behavior of the femur-tissue system can be disregarded provided that the force is applied with very short blows. This needs to be considered for any attempt to replace the mallet in the operation theater (e.g. automated surgical impaction tools) or to modify the mallet (e.g. alternative tip material). Furthermore, it may provide guidance on the fixation of femurs in in vitro testing to mimic surgical reality.

Authors

Institutions

Publication Details

Journal
Clinical Biomechanics
Published
2025-04-20
DOI
https://doi.org/10.1016/j.clinbiomech.2025.106530
Citations
1
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic response of soft tissue can be disregarded during femoral stem impaction

Gerd Huber, Johann Zwirner, Benjamin Ondruschka, Peter J. Schlieker et al.
1 citations
Clinical Biomechanics
Orthopaedic implants and arthroplasty
2.01
article

Dynamic response of soft tissue can be disregarded during femoral stem impaction

Gerd Huber, Johann Zwirner, Benjamin Ondruschka, Peter J. Schlieker, Michael M. Morlock, Frank Lampe
article en
1 citations

Abstract

Common metal-on-metal mallet blows in surgery are very short and mostly excite high frequencies that are clearly above the natural frequency of the femur-tissue system. Those overcritical force impulses make the stem slide into the femur before the bone can even start moving. Hence, the individual mechanical behavior of the femur-tissue system can be disregarded provided that the force is applied with very short blows. This needs to be considered for any attempt to replace the mallet in the operation theater (e.g. automated surgical impaction tools) or to modify the mallet (e.g. alternative tip material). Furthermore, it may provide guidance on the fixation of femurs in in vitro testing to mimic surgical reality.

Clinical BiomechanicsVol. 125
Universität Hamburg (DE), University Medical Center Hamburg-Eppendorf (DE), Asklepios Klinik Barmbek (DE), Hamburg University of Technology (DE)
Openalex Percentile: Top 17%
Orthopaedic implants and arthroplasty
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.