Converting waste into value. Stability of leftover EDTA whole blood: serum <i>vs.</i> plasma for nine clinical chemistry analyses

This study evaluates the utility of leftover EDTA whole blood from a diagnostic biobank for determining concentrations of ferritin, cobalamin, homocysteine, hCG, and thyroid-related hormones and antibodies (TSH, fT4, fT3, TRAb, and anti-TPO). Twenty participants were included. Pre-analytical bias in their blood samples was assessed as per European Federation of Clinical Chemistry and Laboratory Medicine Milano performance specifications. We evaluated the stability of EDTA whole blood stored at various intervals (days 0, 1, 6, and 13), and compared plasma derived from these samples with serum samples. Bland Altman plots and Paired <i>t</i>-test were used to identify statistically significant differences. We found good quantitative agreement, with biases within set performance specifications for cobalamin (14%), fT4 (3.5%), fT3 (3.6%), TSH (15%), and ferritin (7.4%). The calculated biases for serum <i>vs.</i> EDTA plasma day 6 were as follows: cobalamin 1.9%, fT4 2.6%, fT3 0.4%, TSH -2.1%, and ferritin -4.5%. The biases for homocysteine exceeded limits in all comparisons, except serum <i>vs.</i> EDTA plasma on day 0 and between EDTA plasma from day 0 and day 1. The calculated bias of 41% exceeded the set limit of 13% when comparing serum with EDTA plasma day 6. For hCG, anti-TPO, and TRAb, limited measurable levels restricted bias calculations. As per the diagnostic biobank protocols, EDTA blood stored for up to 6 days provides plasma suitable for analyzing cobalamin, fT4, fT3, TSH, and ferritin. Our study confirms previous findings that homocysteine has poor stability in whole blood.

Authors

Institutions

Publication Details

Journal
Scandinavian Journal of Clinical and Laboratory Investigation
Published
2025-04-03
DOI
https://doi.org/10.1080/00365513.2025.2494261
Citations
1
Primary Topic
Healthcare cost, quality, practices
Type
article
Field-Weighted Citation Impact
2.82
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Converting waste into value. Stability of leftover EDTA whole blood: serum vs. plasma for nine clinical chemistry analyses

Tor Arne Strand, Inger Granberg, Kjersti Sletten Bakken, Ragnhild Røysland et al.
1 citations
Scandinavian Journal of Clinical and Laboratory Investigation
Healthcare cost, quality, practices
2.82
article

Converting waste into value. Stability of leftover EDTA whole blood: serum vs. plasma for nine clinical chemistry analyses

Tor Arne Strand, Inger Granberg, Kjersti Sletten Bakken, Ragnhild Røysland, Cindhya Sithiravel, Ingunn Tjelde Fauskrud, Hege K. Tjølsen Hermansen
article en
1 citations

Abstract

This study evaluates the utility of leftover EDTA whole blood from a diagnostic biobank for determining concentrations of ferritin, cobalamin, homocysteine, hCG, and thyroid-related hormones and antibodies (TSH, fT4, fT3, TRAb, and anti-TPO). Twenty participants were included. Pre-analytical bias in their blood samples was assessed as per European Federation of Clinical Chemistry and Laboratory Medicine Milano performance specifications. We evaluated the stability of EDTA whole blood stored at various intervals (days 0, 1, 6, and 13), and compared plasma derived from these samples with serum samples. Bland Altman plots and Paired <i>t</i>-test were used to identify statistically significant differences. We found good quantitative agreement, with biases within set performance specifications for cobalamin (14%), fT4 (3.5%), fT3 (3.6%), TSH (15%), and ferritin (7.4%). The calculated biases for serum <i>vs.</i> EDTA plasma day 6 were as follows: cobalamin 1.9%, fT4 2.6%, fT3 0.4%, TSH -2.1%, and ferritin -4.5%. The biases for homocysteine exceeded limits in all comparisons, except serum <i>vs.</i> EDTA plasma on day 0 and between EDTA plasma from day 0 and day 1. The calculated bias of 41% exceeded the set limit of 13% when comparing serum with EDTA plasma day 6. For hCG, anti-TPO, and TRAb, limited measurable levels restricted bias calculations. As per the diagnostic biobank protocols, EDTA blood stored for up to 6 days provides plasma suitable for analyzing cobalamin, fT4, fT3, TSH, and ferritin. Our study confirms previous findings that homocysteine has poor stability in whole blood.

Scandinavian Journal of Clinical and Laboratory InvestigationVol. 85(3)
University of Oslo (NO), Innlandet Hospital Trust (NO), Akershus University Hospital (NO), University of Bergen (NO)
Responsible consumption and production
Openalex Percentile: Top 12%
Healthcare cost, quality, practices
2.82
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.