Dosimetric comparison of coplanar and noncoplanar volumetric modulated arc therapy for ovarian-sparing cervical cancer radiation therapy

Cervical cancer radiotherapy in young patients risks premature ovarian failure. Ovarian-sparing techniques (OS-CRT) are critical for preserving fertility and endocrine function, yet optimal planning strategies remain underexplored. To compare dosimetric outcomes, efficiency, and plan quality between coplanar (C-VMAT) and non-coplanar VMAT (NC-VMAT) using two treatment planning systems (TPS): Monaco (Elekta Infinity) and uRT-TPOIS (uRT-linac 506c). Four plans (MC-CVMAT, MC-NCVMAT, UT-CVMAT, UT-NCVMAT) were designed for 20 cervical cancer patients with bilateral ovarian transposition. Dosimetric parameters (PTV D0.03 cc, Dmean, HI, CI; ovarian Dmax/Dmean), plan complexity (modulation complexity score, MCS), delivery efficiency (beam-on time, BOT; monitor units, MU), and plan quality metrics (PQM) were evaluated. Statistical analysis included ANOVA and non-parametric tests. All plans met clinical constraints. NC-VMAT showed marginally lower PTV D0.03 cc (48.45 ± 0.48 Gy vs. 48.71 ± 0.38 Gy, p = 0.063) and improved bowel bag Dmean (20.0 ± 2.3 Gy vs. 24.1 ± 3.5 Gy, p < 0.001) but increased BOT (114s vs. 86s for uRT-TPOIS; 233s vs. 193s for Monaco). C-VMAT demonstrated superior efficiency (optimization time: 15–40 min) and lower complexity (MCS = 0.335 vs. 0.222 for NC-VMAT). uRT-TPOIS achieved better CI (0.89 vs. 0.87, p < 0.001) and bowel sparing, while Monaco reduced bladder/rectal D2cc (47.27 ± 0.39 Gy vs. 47.52 ± 0.32 Gy, p < 0.05). No significant differences in PQM were observed. C-VMAT is preferred for OS-CRT due to balanced efficiency and dosimetry. uRT-TPOIS excels in rapid optimization and image guidance, whereas Monaco offers superior OAR protection. These findings provide clinically actionable insights for ovarian function preservation.

Authors

Institutions

Publication Details

Journal
Journal of Radiation Research and Applied Sciences
Published
2025-04-20
DOI
https://doi.org/10.1016/j.jrras.2025.101531
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dosimetric comparison of coplanar and noncoplanar volumetric modulated arc therapy for ovarian-sparing cervical cancer radiation therapy

Xiaolong Cheng, Binbing Wang, Long Sun, Jiping Liu
Journal of Radiation Research and Applied Sciences
Advanced Radiotherapy Techniques
article

Dosimetric comparison of coplanar and noncoplanar volumetric modulated arc therapy for ovarian-sparing cervical cancer radiation therapy

Xiaolong Cheng, Binbing Wang, Long Sun, Jiping Liu
article en

Abstract

Cervical cancer radiotherapy in young patients risks premature ovarian failure. Ovarian-sparing techniques (OS-CRT) are critical for preserving fertility and endocrine function, yet optimal planning strategies remain underexplored. To compare dosimetric outcomes, efficiency, and plan quality between coplanar (C-VMAT) and non-coplanar VMAT (NC-VMAT) using two treatment planning systems (TPS): Monaco (Elekta Infinity) and uRT-TPOIS (uRT-linac 506c). Four plans (MC-CVMAT, MC-NCVMAT, UT-CVMAT, UT-NCVMAT) were designed for 20 cervical cancer patients with bilateral ovarian transposition. Dosimetric parameters (PTV D0.03 cc, Dmean, HI, CI; ovarian Dmax/Dmean), plan complexity (modulation complexity score, MCS), delivery efficiency (beam-on time, BOT; monitor units, MU), and plan quality metrics (PQM) were evaluated. Statistical analysis included ANOVA and non-parametric tests. All plans met clinical constraints. NC-VMAT showed marginally lower PTV D0.03 cc (48.45 ± 0.48 Gy vs. 48.71 ± 0.38 Gy, p = 0.063) and improved bowel bag Dmean (20.0 ± 2.3 Gy vs. 24.1 ± 3.5 Gy, p < 0.001) but increased BOT (114s vs. 86s for uRT-TPOIS; 233s vs. 193s for Monaco). C-VMAT demonstrated superior efficiency (optimization time: 15–40 min) and lower complexity (MCS = 0.335 vs. 0.222 for NC-VMAT). uRT-TPOIS achieved better CI (0.89 vs. 0.87, p < 0.001) and bowel sparing, while Monaco reduced bladder/rectal D2cc (47.27 ± 0.39 Gy vs. 47.52 ± 0.32 Gy, p < 0.05). No significant differences in PQM were observed. C-VMAT is preferred for OS-CRT due to balanced efficiency and dosimetry. uRT-TPOIS excels in rapid optimization and image guidance, whereas Monaco offers superior OAR protection. These findings provide clinically actionable insights for ovarian function preservation.

Journal of Radiation Research and Applied SciencesVol. 18(2)
Zhejiang Cancer Hospital (CN)
Good health and well-being
Openalex Percentile: Top 90%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Dosimetric comparison of coplanar and noncoplanar volumetric modulated arc therapy for ovarian-sparing cervical cancer radiation therapy — Xiaolong Cheng, Binbing Wang, et al. · Journal of Radiation Research and Applied Sciences (2025) | TGRS Research Map | TGRS