Mitigating Subsynchronous Resonance in Doubly Fed Wind Turbine Induction Generator Using FACTS Devices: A Comparative Case Study

Sub-synchronous resonance (SSR) may result from the recent integration of wind power generating systems (WPGS) based on double-fed induction generators (DFIG) into weak grids using long transmission lines with series capacitor adjustment. The amount of series compensation used in the transmission line determines how much SSR affects the grid, which may lead to serious instability. Flexible alternating current transmission system (FACTS) devices, which aid in controlling and stabilizing grid oscillations, are a workable way to lessen the impacts of SSR. In order to analyze the efficacy of FACTS controllers in mitigating SSR, this work examines the modeling and control techniques of WPGS-DFIG employing Thyristor controlled series capacitor (TCSC), static Var compensator (SVC), and static synchronous compensator (STATCOM). Time-domain simulations on a modified IEEE First benchmark, with varying series compensation levels and grid fault circumstances, are used to verify the study's correctness and effectiveness. According to the simulation findings, the STATCOM controller mitigates SSR far more effectively than TCSC and SVC. The STATCOM controller optimizes the performance of the WPGS-DFIG system by increasing dynamic responsiveness and grid stability in SSR-prone conditions.

Authors

Publication Details

Journal
International Journal of Robotics and Control Systems
Published
2024-12-24
DOI
https://doi.org/10.31763/ijrcs.v5i1.1436
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mitigating Subsynchronous Resonance in Doubly Fed Wind Turbine Induction Generator Using FACTS Devices: A Comparative Case Study

Lê Văn Đại, Thanh Tran, Pham Thanh, Bui Thi Hoa Phuong
International Journal of Robotics and Control Systems
Power Systems and Renewable Energy
article

Mitigating Subsynchronous Resonance in Doubly Fed Wind Turbine Induction Generator Using FACTS Devices: A Comparative Case Study

Lê Văn Đại, Thanh Tran, Pham Thanh, Bui Thi Hoa Phuong
article en

Abstract

Sub-synchronous resonance (SSR) may result from the recent integration of wind power generating systems (WPGS) based on double-fed induction generators (DFIG) into weak grids using long transmission lines with series capacitor adjustment. The amount of series compensation used in the transmission line determines how much SSR affects the grid, which may lead to serious instability. Flexible alternating current transmission system (FACTS) devices, which aid in controlling and stabilizing grid oscillations, are a workable way to lessen the impacts of SSR. In order to analyze the efficacy of FACTS controllers in mitigating SSR, this work examines the modeling and control techniques of WPGS-DFIG employing Thyristor controlled series capacitor (TCSC), static Var compensator (SVC), and static synchronous compensator (STATCOM). Time-domain simulations on a modified IEEE First benchmark, with varying series compensation levels and grid fault circumstances, are used to verify the study's correctness and effectiveness. According to the simulation findings, the STATCOM controller mitigates SSR far more effectively than TCSC and SVC. The STATCOM controller optimizes the performance of the WPGS-DFIG system by increasing dynamic responsiveness and grid stability in SSR-prone conditions.

International Journal of Robotics and Control SystemsVol. 5(1)
Openalex Percentile: Top 63%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Mitigating Subsynchronous Resonance in Doubly Fed Wind Turbine Induction Generator Using FACTS Devices: A Comparative Case Study — Lê Văn Đại, Thanh Tran, et al. · International Journal of Robotics and Control Systems (2024) | TGRS Research Map | TGRS