SPR-based refractive index sensor design with grated Au-ZnS for dengue detection using machine learning

In this paper, we propose a Surface Plasmon Resonance (SPR) fiber optic refractive index (RI) sensor. It consists of a multi-mode fiber (MMF) sensor with a bi-metallic nanostructure with Gold (Au) and Zinc Sulphide (ZnS) as the plasmonic sensing layer. The effect of the design parameter variation is evaluated to achieve the maximum wavelength sensitivity (WS). The testing sample's RI is taken from 1.34 to 1.40. We found that RI sensitivity varies non-linearly from 9000 to 18,000 nm/RIU. This sensor is additionally capable of detecting the dengue virus with a highest WS of 14285.71 nm/RIU for the infected haemoglobin. Moreover, the incorporation of machine learning (ML) techniques signifies a substantial progression in sensor design. The neural network (NN) model exhibited best performance, with a minimal mean square error (MSE) of 0.2828 and an R<sup>2</sup> value of 0.9998. These algorithms offer flexible adaptation and the derivation of insights based on data, enhancing the sensor's effectiveness in forecasting resonance wavelength (RW) for various analytes, as well as errors, classification metrics like accuracy, precision, F1_score, and computation duration. Performance metrics such as Detection Accuracy (DA), Figure of Merit (FOM), signal-to-noise ratio (SNR) and quality factor (QF) are also determined having maximum values 14.285 μm<sup>-1</sup>, 158.73 RIU<sup>-1</sup>, 5.55 and 79365.055 nm/RIU respectively. The recommended biosensor, which uses the NN model, performed better than all the other models and may be used to biological applications.

Authors

Institutions

Publication Details

Journal
Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy
Published
2025-04-19
DOI
https://doi.org/10.1016/j.saa.2025.126276
Citations
8
Primary Topic
Mosquito-borne diseases and control
Type
article
Field-Weighted Citation Impact
15.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SPR-based refractive index sensor design with grated Au-ZnS for dengue detection using machine learning

Jaisingh Thangaraj, Ananya Banerjee
8 citations
Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy
Mosquito-borne diseases and control
15.03
article

SPR-based refractive index sensor design with grated Au-ZnS for dengue detection using machine learning

Jaisingh Thangaraj, Ananya Banerjee
article en
8 citations

Abstract

In this paper, we propose a Surface Plasmon Resonance (SPR) fiber optic refractive index (RI) sensor. It consists of a multi-mode fiber (MMF) sensor with a bi-metallic nanostructure with Gold (Au) and Zinc Sulphide (ZnS) as the plasmonic sensing layer. The effect of the design parameter variation is evaluated to achieve the maximum wavelength sensitivity (WS). The testing sample's RI is taken from 1.34 to 1.40. We found that RI sensitivity varies non-linearly from 9000 to 18,000 nm/RIU. This sensor is additionally capable of detecting the dengue virus with a highest WS of 14285.71 nm/RIU for the infected haemoglobin. Moreover, the incorporation of machine learning (ML) techniques signifies a substantial progression in sensor design. The neural network (NN) model exhibited best performance, with a minimal mean square error (MSE) of 0.2828 and an R<sup>2</sup> value of 0.9998. These algorithms offer flexible adaptation and the derivation of insights based on data, enhancing the sensor's effectiveness in forecasting resonance wavelength (RW) for various analytes, as well as errors, classification metrics like accuracy, precision, F1_score, and computation duration. Performance metrics such as Detection Accuracy (DA), Figure of Merit (FOM), signal-to-noise ratio (SNR) and quality factor (QF) are also determined having maximum values 14.285 μm<sup>-1</sup>, 158.73 RIU<sup>-1</sup>, 5.55 and 79365.055 nm/RIU respectively. The recommended biosensor, which uses the NN model, performed better than all the other models and may be used to biological applications.

Spectrochimica Acta Part A Molecular and Biomolecular SpectroscopyVol. 339
Indian Institute of Technology Dhanbad (IN)
Openalex Percentile: Top 1%
Mosquito-borne diseases and control
15.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.