Seasonal analysis of boil-off gas rates in liquid hydrogen storage tank using time-series analysis

The storage of liquid hydrogen (LH 2 ) in stationary tanks poses significant challenges due to boil-off gas (BOG) losses caused by heat ingress from the external environment. This study aimed to analyze the boil-off rate (BoR) of an LH 2 tank across four different seasons summer, winter, autumn and spring using daily temperature profiles to examine seasonal variations in heat transfer and their impact on hydrogen losses. A stationary LH 2 tank with a volume of 5.6 m 3 with multilayer insulation (MLI) and high vacuum conditions was modeled to simulate heat ingress and resulting BoR. Temperature data spanning 24 h of selective day for each season were collected and analyzed using time-series analysis, a statistical technique for examining and forecasting non-stationary data trends over time converted to a dataset. Historical temperature data were leveraged to predict seasonal variations in heat ingress and BOG generation. Additionally, the system was modeled and simulated using the software Ansys Twin Builder to accurately replicate the dynamic behavior of the tank under varying thermal conditions. An LH 2 tank is modeled using Python language and then interfaced with the twin builder and for the BOG collection tank the Modelica's vessel component is used. The simulations demonstrated that the BoR exhibited significant fluctuations across the seasons, with the highest rates observed during summer due to increased ambient temperatures and reduced during winter due to lower thermal gradients. Spring and autumn(fall) showed intermediate BoR values, influenced by moderate temperature variations. The time-series analysis provided precise insights into the daily patterns of temperature-driven boil-off, validating the predictive capability of the model. The developed model successfully quantified the impact of seasonal temperature variations on LH 2 boil-off in stationary tanks, offering a robust tool for optimizing insulation strategies and BOG management. The findings underscored the importance of Thermal Management Systems (TMS) for minimizing hydrogen losses in the future, thereby enhancing the viability of LH 2 tanks in airport fuel for hydrogen-powered aircraft.

Authors

Institutions

Publication Details

Journal
International Journal of Hydrogen Energy
Published
2025-04-19
DOI
https://doi.org/10.1016/j.ijhydene.2025.04.275
Citations
4
Primary Topic
Spacecraft and Cryogenic Technologies
Type
article
Field-Weighted Citation Impact
19.97
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seasonal analysis of boil-off gas rates in liquid hydrogen storage tank using time-series analysis

Pasquale Daniele Cavaliere, K. Ravichandran
4 citations
International Journal of Hydrogen Energy
Spacecraft and Cryogenic Technologies
19.97
article

Seasonal analysis of boil-off gas rates in liquid hydrogen storage tank using time-series analysis

Pasquale Daniele Cavaliere, K. Ravichandran
article en
4 citations

Abstract

The storage of liquid hydrogen (LH 2 ) in stationary tanks poses significant challenges due to boil-off gas (BOG) losses caused by heat ingress from the external environment. This study aimed to analyze the boil-off rate (BoR) of an LH 2 tank across four different seasons summer, winter, autumn and spring using daily temperature profiles to examine seasonal variations in heat transfer and their impact on hydrogen losses. A stationary LH 2 tank with a volume of 5.6 m 3 with multilayer insulation (MLI) and high vacuum conditions was modeled to simulate heat ingress and resulting BoR. Temperature data spanning 24 h of selective day for each season were collected and analyzed using time-series analysis, a statistical technique for examining and forecasting non-stationary data trends over time converted to a dataset. Historical temperature data were leveraged to predict seasonal variations in heat ingress and BOG generation. Additionally, the system was modeled and simulated using the software Ansys Twin Builder to accurately replicate the dynamic behavior of the tank under varying thermal conditions. An LH 2 tank is modeled using Python language and then interfaced with the twin builder and for the BOG collection tank the Modelica's vessel component is used. The simulations demonstrated that the BoR exhibited significant fluctuations across the seasons, with the highest rates observed during summer due to increased ambient temperatures and reduced during winter due to lower thermal gradients. Spring and autumn(fall) showed intermediate BoR values, influenced by moderate temperature variations. The time-series analysis provided precise insights into the daily patterns of temperature-driven boil-off, validating the predictive capability of the model. The developed model successfully quantified the impact of seasonal temperature variations on LH 2 boil-off in stationary tanks, offering a robust tool for optimizing insulation strategies and BOG management. The findings underscored the importance of Thermal Management Systems (TMS) for minimizing hydrogen losses in the future, thereby enhancing the viability of LH 2 tanks in airport fuel for hydrogen-powered aircraft.

International Journal of Hydrogen EnergyVol. 128
University of Salento (IT), Innovation Engineering (Italy) (IT), University of Oulu (FI)
Openalex Percentile: Top 1%
Spacecraft and Cryogenic Technologies
19.97
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.