Outer lumen arterial imaging with CTA: A potential tool to diagnose vertebral artery dissection

Differentiating vertebral artery dissection (VAD) from vertebral artery hypoplasia (VAH) can be difficult with standard CT/CTA imaging. However, making this distinction is critical to providing appropriate patient management. In this brief report/technical note, we describe a new 3D CTA postprocessing technique to potentially distinguish VAD from VAH. We describe a case of right-sided VAD, where the initially rendered 3D images demonstrated a small inner lumen of the vertebral artery (VA). With this technique, VAD and VAH can potentially be conflated as the inner lumens in both conditions are narrow. A subsequent set of 3D images highlighted the outer lumen, which was relatively preserved - a finding in VAD but not VAH. With the proliferation of CTA imaging in the emergency setting, this 3D post processing technique can serve as an invaluable tool. Moreover, this technique offers the potential to be expanded and improved upon by utilizing deep learning (DL)-based segmentation.

Authors

Institutions

Publication Details

Journal
Radiology Case Reports
Published
2025-04-19
DOI
https://doi.org/10.1016/j.radcr.2025.03.041
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Outer lumen arterial imaging with CTA: A potential tool to diagnose vertebral artery dissection

Ian T. Mark, Joseph George, Girish Bathla
Radiology Case Reports
Intracranial Aneurysms: Treatment and Complications
article

Outer lumen arterial imaging with CTA: A potential tool to diagnose vertebral artery dissection

Ian T. Mark, Joseph George, Girish Bathla
article en

Abstract

Differentiating vertebral artery dissection (VAD) from vertebral artery hypoplasia (VAH) can be difficult with standard CT/CTA imaging. However, making this distinction is critical to providing appropriate patient management. In this brief report/technical note, we describe a new 3D CTA postprocessing technique to potentially distinguish VAD from VAH. We describe a case of right-sided VAD, where the initially rendered 3D images demonstrated a small inner lumen of the vertebral artery (VA). With this technique, VAD and VAH can potentially be conflated as the inner lumens in both conditions are narrow. A subsequent set of 3D images highlighted the outer lumen, which was relatively preserved - a finding in VAD but not VAH. With the proliferation of CTA imaging in the emergency setting, this 3D post processing technique can serve as an invaluable tool. Moreover, this technique offers the potential to be expanded and improved upon by utilizing deep learning (DL)-based segmentation.

Radiology Case ReportsVol. 20(7)
Mayo Clinic in Arizona (US)
Openalex Percentile: Top 86%
Intracranial Aneurysms: Treatment and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.