[Torso Simulation Research on Electromagnetic Compatibility of Implantable Neurostimulator].

In the YY 0989.3-2023 standard, clause 27.106 specifies the protection test against electromagnetic interference, but it only briefly describes the test level for electromagnetic exposure, and does not detail the parameters of the torso. This study aims to explore the internal field distribution for different torso parameters under electromagnetic exposure, and explore the patterns of field distribution through modeling and simulation. The results indicate that the parameters of the torso significantly affect the internal field distribution. The findings of this study provide a basis and reference for the electromagnetic compatibility test for implantable neurostimulator products.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2025-03-30
DOI
https://doi.org/10.12455/j.issn.1671-7104.230726
Primary Topic
Pain Management and Treatment
Type
article
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[Torso Simulation Research on Electromagnetic Compatibility of Implantable Neurostimulator].

Jiawei Liu, Weiming Wang, Weiqiang Zhang, Li‐Xin Dai et al.
PubMed
Pain Management and Treatment
article

[Torso Simulation Research on Electromagnetic Compatibility of Implantable Neurostimulator].

Jiawei Liu, Weiming Wang, Weiqiang Zhang, Li‐Xin Dai, Qifei Li
article en

Abstract

In the YY 0989.3-2023 standard, clause 27.106 specifies the protection test against electromagnetic interference, but it only briefly describes the test level for electromagnetic exposure, and does not detail the parameters of the torso. This study aims to explore the internal field distribution for different torso parameters under electromagnetic exposure, and explore the patterns of field distribution through modeling and simulation. The results indicate that the parameters of the torso significantly affect the internal field distribution. The findings of this study provide a basis and reference for the electromagnetic compatibility test for implantable neurostimulator products.

PubMedVol. 49(2)
Shanghai Medical College of Fudan University (CN), Fudan University (CN), The Medical Device (United Kingdom) (GB)
Pain Management and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

[Torso Simulation Research on Electromagnetic Compatibility of Implantable Neurostimulator]. — Jiawei Liu, Weiming Wang, et al. · PubMed (2025) | TGRS Research Map | TGRS