Direct liquid cooling in compact machines: Advantages and limitations

The increasing demand for more efficient propulsion systems in electric and hybrid vehicles necessitates advanced thermal management in compact electric machines. This study investigates a novel direct liquid cooling (DLC) approach using Litz copper wires braided around a stainless steel tube to enhance heat removal. Analytical model, numerical simulations, and experimental testing were employed to evaluate the system’s cooling efficiency, considering various conductor sizes and supply currents. The results show that direct liquid cooling significantly lowers winding temperatures compared to traditional cooling methods when operating at the same load. These temperature dependencies are explored in more detail in the paper using the developed analytical approach. The analytical model, which was verified with experimental results, also indicates that direct liquid cooling windings can support up to 277% more current than traditional water jacket-cooled windings while maintaining a maximum temperature of 70 °C. These findings demonstrate that direct liquid cooling windings are a highly effective method for enhancing thermal performance even in compact motors, enabling higher power densities. • Direct liquid cooling has been shown to enable higher current density in the winding. • The operating temperature of the winding can be reduced using direct liquid cooling. • The minimum feasible size of direct liquid cooling layout in a motor was defined. • The developed analytical model evaluates cooling effectiveness and motor efficiency. • The optimal conditions for direct liquid cooling in electric motors were identified.

Authors

Institutions

Publication Details

Journal
Applied Thermal Engineering
Published
2025-04-19
DOI
https://doi.org/10.1016/j.applthermaleng.2025.126461
Citations
3
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
2.14
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct liquid cooling in compact machines: Advantages and limitations

Juha Pyrhönen, Hüseyin Tayyer Canseven, Ilya Petrov, Andrea Credo et al.
3 citations
Applied Thermal Engineering
Heat Transfer and Optimization
2.14
article

Direct liquid cooling in compact machines: Advantages and limitations

Juha Pyrhönen, Hüseyin Tayyer Canseven, Ilya Petrov, Andrea Credo, Shruti Singh, Timo Nykänen
article en
3 citations

Abstract

The increasing demand for more efficient propulsion systems in electric and hybrid vehicles necessitates advanced thermal management in compact electric machines. This study investigates a novel direct liquid cooling (DLC) approach using Litz copper wires braided around a stainless steel tube to enhance heat removal. Analytical model, numerical simulations, and experimental testing were employed to evaluate the system’s cooling efficiency, considering various conductor sizes and supply currents. The results show that direct liquid cooling significantly lowers winding temperatures compared to traditional cooling methods when operating at the same load. These temperature dependencies are explored in more detail in the paper using the developed analytical approach. The analytical model, which was verified with experimental results, also indicates that direct liquid cooling windings can support up to 277% more current than traditional water jacket-cooled windings while maintaining a maximum temperature of 70 °C. These findings demonstrate that direct liquid cooling windings are a highly effective method for enhancing thermal performance even in compact motors, enabling higher power densities. • Direct liquid cooling has been shown to enable higher current density in the winding. • The operating temperature of the winding can be reduced using direct liquid cooling. • The minimum feasible size of direct liquid cooling layout in a motor was defined. • The developed analytical model evaluates cooling effectiveness and motor efficiency. • The optimal conditions for direct liquid cooling in electric motors were identified.

Applied Thermal EngineeringVol. 273
University of L'Aquila (IT), Lappeenranta-Lahti University of Technology (FI)
Affordable and clean energy
Openalex Percentile: Top 14%
Heat Transfer and Optimization
2.14
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.