Indoor Air Background Concentrations of Volatile Organic Compounds ( <scp>VOCs</scp> ) in California Residences

Abstract A study was performed to measure typical “indoor air background” concentrations of volatile organic compounds (VOCs) in residential buildings in the state of California that were not known to be impacted by subsurface sources. A total of 57 buildings were sampled between February 2023 and February 2024, with one sample collected per building. The data set represents 38 different cities within the state of California. The samples were analyzed using the United States Environmental Protection Agency (EPA) Method TO‐15 (EPA 1999) in both full‐scan and Selected Ion Monitoring (SIM) modes. A total of 105 individual VOCs were reported for each sample. The overall data set is 5985 individual data points, with concentrations of target compound VOCs reported from less than the laboratory method reporting limit of 0.044 μg/m 3 (micrograms per cubic meter) to concentrations up to 14,000 μg/m 3 . Various VOCs were detected at concentrations above screening levels used in California and elsewhere in the United States, including Benzene, Naphthalene, Tetrachloroethene (PCE), and Trichloroethene (TCE). These compounds are often considered “risk drivers” in vapor intrusion (VI) studies, so their presence in background air at concentrations above screening levels may complicate such studies. Compared with previous, similar studies, this study is more comprehensive with a larger number of VOCs analyzed and with greater analytical sensitivity. Based on the professional backgrounds of the study group which included environmental professionals, regulatory officials, and attorneys, the authors opine that the results of this residential indoor air background study may be biased low relative to the general population. Therefore, the results of the Study are considered to reflect a conservative snapshot of indoor air background VOCs in California residences.

Authors

Publication Details

Journal
Groundwater Monitoring & Remediation
Published
2025-03-01
DOI
https://doi.org/10.1111/gwmr.12719
Citations
4
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
4.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Indoor Air Background Concentrations of Volatile Organic Compounds ( VOCs ) in California Residences

Bart Eklund, Gina Plantz, Heidi Hayes, Rich Rago et al.
4 citations
Groundwater Monitoring & Remediation
Indoor Air Quality and Microbial Exposure
4.80
article

Indoor Air Background Concentrations of Volatile Organic Compounds ( VOCs ) in California Residences

Bart Eklund, Gina Plantz, Heidi Hayes, Rich Rago, Minh-Chien Tran, Kelly Chatterton
article en
4 citations

Abstract

Abstract A study was performed to measure typical “indoor air background” concentrations of volatile organic compounds (VOCs) in residential buildings in the state of California that were not known to be impacted by subsurface sources. A total of 57 buildings were sampled between February 2023 and February 2024, with one sample collected per building. The data set represents 38 different cities within the state of California. The samples were analyzed using the United States Environmental Protection Agency (EPA) Method TO‐15 (EPA 1999) in both full‐scan and Selected Ion Monitoring (SIM) modes. A total of 105 individual VOCs were reported for each sample. The overall data set is 5985 individual data points, with concentrations of target compound VOCs reported from less than the laboratory method reporting limit of 0.044 μg/m 3 (micrograms per cubic meter) to concentrations up to 14,000 μg/m 3 . Various VOCs were detected at concentrations above screening levels used in California and elsewhere in the United States, including Benzene, Naphthalene, Tetrachloroethene (PCE), and Trichloroethene (TCE). These compounds are often considered “risk drivers” in vapor intrusion (VI) studies, so their presence in background air at concentrations above screening levels may complicate such studies. Compared with previous, similar studies, this study is more comprehensive with a larger number of VOCs analyzed and with greater analytical sensitivity. Based on the professional backgrounds of the study group which included environmental professionals, regulatory officials, and attorneys, the authors opine that the results of this residential indoor air background study may be biased low relative to the general population. Therefore, the results of the Study are considered to reflect a conservative snapshot of indoor air background VOCs in California residences.

Groundwater Monitoring & RemediationVol. 45(2)
Openalex Percentile: Top 6%
Indoor Air Quality and Microbial Exposure
4.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.