Dissolved Gas Analysis on POME-based Nanofluids

This paper investigates the dissolved gas analysis (DGA) of aged palm oil methyl ester (POME)-based nanofluids. Thermal stress is applied to nanofluids with various concentrations of TiO2 and MWCNT nanoparticles. The experiments are conducted on a laboratory scale, with the POME-based nanofluids thermally aged at 130 oC in the absence of solid insulating materials. The study aims to compare the gases generated in both nanofluids. Four different diagnosis methods are employed: Rogers Ratio, IEC Gas Ratio, Duval Triangle, and Duval Pentagon. The experimental results reveal nearly identical gassing behaviors between the two nanofluids after thermal ageing. These findings contribute to expanding investigations into transformer fault diagnosis, particularly in cases where various natural ester oils, including POME-based nanofluids, are used in power transformer. This helps diversify the growing body of research on DGA for natural ester oils, which has largely focused on commercially dominant types.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Dielectrics and Electrical Insulation
Published
2025-01-01
DOI
https://doi.org/10.1109/tdei.2025.3562171
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dissolved Gas Analysis on POME-based Nanofluids

Siti Kudnie Sahari, Asrani Lit, Nurul ‘Izzati Hashim, Yanuar Z. Arief et al.
IEEE Transactions on Dielectrics and Electrical Insulation
High voltage insulation and dielectric phenomena
article

Dissolved Gas Analysis on POME-based Nanofluids

Siti Kudnie Sahari, Asrani Lit, Nurul ‘Izzati Hashim, Yanuar Z. Arief, Nur Sabrina Suhaimi, Sharifah Masniah Wan Masra, Nazreen Junaidi, Elaf Musa, S. Umang
article en

Abstract

This paper investigates the dissolved gas analysis (DGA) of aged palm oil methyl ester (POME)-based nanofluids. Thermal stress is applied to nanofluids with various concentrations of TiO2 and MWCNT nanoparticles. The experiments are conducted on a laboratory scale, with the POME-based nanofluids thermally aged at 130 oC in the absence of solid insulating materials. The study aims to compare the gases generated in both nanofluids. Four different diagnosis methods are employed: Rogers Ratio, IEC Gas Ratio, Duval Triangle, and Duval Pentagon. The experimental results reveal nearly identical gassing behaviors between the two nanofluids after thermal ageing. These findings contribute to expanding investigations into transformer fault diagnosis, particularly in cases where various natural ester oils, including POME-based nanofluids, are used in power transformer. This helps diversify the growing body of research on DGA for natural ester oils, which has largely focused on commercially dominant types.

IEEE Transactions on Dielectrics and Electrical Insulation
Universiti Sains Islam Malaysia (MY), Universiti Malaysia Sarawak (MY)
Ministry of Higher Education, Malaysia
Clean water and sanitation
Openalex Percentile: Top 95%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.