Eliminating Harmonic False Peaks in Fourier Transform Ion Mobility Spectrometry Using a Virtual Ion Gate

Fourier Transform Ion Mobility Spectrometry (FT-IMS) is a widely employed modulation technique that improves ion utilization efficiency compared to conventional pulsed IMS, making it particularly effective for analyzing weak signals. However, traditional FT-IMS encounters significant challenges with harmonic false peaks, which arise from inherent limitations in the modulation and demodulation algorithms, ultimately compromising the accuracy of broad-spectrum analysis. Furthermore, the physical ion gate at the exit of the drift tube contributes to an approximate 20% loss of ions. In this study, these issues are addressed by replacing the physical ion gate with a virtual ion gate and optimizing the fundamental modulation waveform of FT-IMS based on the unique characteristics of the virtual ion gate. By orthogonalizing the fundamental wave, we eliminate the energy component associated with excess frequencies. This modification not only mitigates ion loss but also effectively resolves the harmonic false peaks problem inherent in traditional FT-IMS.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-04-18
DOI
https://doi.org/10.1109/jsen.2025.3560149
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Eliminating Harmonic False Peaks in Fourier Transform Ion Mobility Spectrometry Using a Virtual Ion Gate

Jimin Liang, Yongzheng Yang, Shenghan Ren, Kaitai Guo et al.
IEEE Sensors Journal
Mass Spectrometry Techniques and Applications
article

Eliminating Harmonic False Peaks in Fourier Transform Ion Mobility Spectrometry Using a Virtual Ion Gate

Jimin Liang, Yongzheng Yang, Shenghan Ren, Kaitai Guo, Yang Zheng, Qian Zhang
article en

Abstract

Fourier Transform Ion Mobility Spectrometry (FT-IMS) is a widely employed modulation technique that improves ion utilization efficiency compared to conventional pulsed IMS, making it particularly effective for analyzing weak signals. However, traditional FT-IMS encounters significant challenges with harmonic false peaks, which arise from inherent limitations in the modulation and demodulation algorithms, ultimately compromising the accuracy of broad-spectrum analysis. Furthermore, the physical ion gate at the exit of the drift tube contributes to an approximate 20% loss of ions. In this study, these issues are addressed by replacing the physical ion gate with a virtual ion gate and optimizing the fundamental modulation waveform of FT-IMS based on the unique characteristics of the virtual ion gate. By orthogonalizing the fundamental wave, we eliminate the energy component associated with excess frequencies. This modification not only mitigates ion loss but also effectively resolves the harmonic false peaks problem inherent in traditional FT-IMS.

IEEE Sensors JournalVol. 25(11)
Xidian University (CN)
National Natural Science Foundation of China, Central University Basic Research Fund of China
Affordable and clean energy
Openalex Percentile: Top 92%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.