Procedural Strategies in Transcatheter Aortic Valve Replacement for Patients With Small Aortic Annulus and Aortic Stenosis
Small aortic annulus is recognized as a critical risk factor in transcatheter aortic valve replacement, predisposing patients to prosthesis-patient mismatch. This case series examines 3 distinct anatomical subtypes of small aortic annulus patients undergoing transcatheter aortic valve replacement: 1) tricuspid aortic valve morphology; 2) type 0 bicuspid aortic valve; and 3) failed surgical bioprosthesis. The analysis highlights subtype-specific technical challenges and procedural optimization strategies, emphasizing the importance of preprocedural imaging and prosthesis selection in mitigating complications.
Authors
- Mu Yang (ORCID: https://orcid.org/0000-0001-7091-2281)
- Dongkai Shan (ORCID: https://orcid.org/0000-0002-1453-608X)
- Bo Jiang
- Jing Wang (ORCID: https://orcid.org/0000-0001-9846-7263)
- Yingqian Zhang (ORCID: https://orcid.org/0000-0002-5073-0787)
- Yundai Chen (ORCID: https://orcid.org/0000-0002-3527-5368)
- Zeyu Sun
- Changfu Liu
Institutions
- Chinese PLA General Hospital (CN)
- Tianjin Nankai Hospital (CN)
Publication Details
- Journal
- JACC Case Reports
- Published
- 2025-04-01
- DOI
- https://doi.org/10.1016/j.jaccas.2025.103929
- Primary Topic
- Cardiac Valve Diseases and Treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.00