Validation of magnetic resonance imaging-derived venous oxygen saturation and oxygen consumption measurements during exercise

Accurate measurement of venous oxygen saturation ([Formula: see text]) is fundamental for quantifying oxygen consumption (V̇o<sub>2</sub>) and its Fick determinants. This study evaluated the validity of a novel magnetic resonance imaging (MRI) approach using susceptometry-based oximetry (SBO) to noninvasively measure [Formula: see text] during exercise. First, [Formula: see text] was measured from an antecubital vein in 14 adults (26 ± 5 yr; 8 males) via portable blood analyzer (iSTAT) at rest and during two 5-min bouts of rhythmic handgrip exercise at 30% of maximum voluntary contraction, with temporally matched SBO measures of [Formula: see text] during an identical in-scanner exercise protocol. Separately, 21 adults (27 ± 6 yr; 8 males) completed incremental step ergometry exercise with simultaneous pulmonary V̇o<sub>2</sub> measurement (indirect calorimetry) and MRI-derived V̇o<sub>2</sub> from the Fick determinants (MRI<sub>Fick</sub>), including inferior vena cava [Formula: see text] (SBO) and cardiac output (cardiac MRI). Agreement between methods was assessed by interclass correlation coefficients (ICCs), linear regression, and Bland-Altman plots. There was good to excellent agreement between iSTAT and SBO [Formula: see text] for arm exercise (ICC: 0.86, 95% CI: 0.71-0.93, <i>P</i> < 0.01; mean bias: +5.2%). Test-retest reliability demonstrated excellent agreement for [Formula: see text] measures between trials using iSTAT (ICC: 0.97; 95% CI: 0.93-0.96, <i>P</i> < 0.01; mean bias: -2.7%) and SBO (ICC: 0.90, 95% CI: 0.80-0.95, <i>P</i> < 0.01; mean bias: -0.3%), V̇o<sub>2</sub> calculated from MRI<sub>Fick</sub> demonstrated excellent agreement with pulmonary V̇o<sub>2</sub> (ICC: 0.98, 95% CI: 0.97-0.99, <i>P</i> < 0.01; mean bias: +0.10 L/min). MRI-SBO-derived [Formula: see text] measurements demonstrated excellent reliability and strong agreement with both venous measures and respiratory gas analysis, validating this technique across a wide range of [Formula: see text] values during exercise.<b>NEW & NOTEWORTHY</b> Noninvasive MRI susceptometry-based [Formula: see text] measurements demonstrated excellent repeatability and validity against established direct blood sampling during localized handgrip exercise. The technique's accuracy for determining V̇o<sub>2</sub> during step ergometer exercise was validated through strong agreement between combined cardiac MRI and susceptometry-based Fick calculations and reference pulmonary measures, establishing this method as a reliable tool for noninvasive assessment of oxygen uptake and its Fick determinants across varying exercise intensities.

Authors

Institutions

Publication Details

Journal
American Journal of Physiology-Heart and Circulatory Physiology
Published
2025-04-19
DOI
https://doi.org/10.1152/ajpheart.00134.2025
Citations
3
Primary Topic
Cardiovascular and exercise physiology
Type
article
Field-Weighted Citation Impact
7.14

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of magnetic resonance imaging-derived venous oxygen saturation and oxygen consumption measurements during exercise

Corey R. Tomczak, Stephen Foulkes, André La Gerche, Richard B. Thompson et al.
3 citations
American Journal of Physiology-Heart and Circulatory Physiology
Cardiovascular and exercise physiology
7.14
article

Validation of magnetic resonance imaging-derived venous oxygen saturation and oxygen consumption measurements during exercise

Corey R. Tomczak, Stephen Foulkes, André La Gerche, Richard B. Thompson, Dean R. Perkins, Rachel J. Skow, Mark J. Haykowsky, Justin S. Lawley, Michael D. Nelson, Hendrik Mugele
article en
3 citations

Abstract

Accurate measurement of venous oxygen saturation ([Formula: see text]) is fundamental for quantifying oxygen consumption (V̇o<sub>2</sub>) and its Fick determinants. This study evaluated the validity of a novel magnetic resonance imaging (MRI) approach using susceptometry-based oximetry (SBO) to noninvasively measure [Formula: see text] during exercise. First, [Formula: see text] was measured from an antecubital vein in 14 adults (26 ± 5 yr; 8 males) via portable blood analyzer (iSTAT) at rest and during two 5-min bouts of rhythmic handgrip exercise at 30% of maximum voluntary contraction, with temporally matched SBO measures of [Formula: see text] during an identical in-scanner exercise protocol. Separately, 21 adults (27 ± 6 yr; 8 males) completed incremental step ergometry exercise with simultaneous pulmonary V̇o<sub>2</sub> measurement (indirect calorimetry) and MRI-derived V̇o<sub>2</sub> from the Fick determinants (MRI<sub>Fick</sub>), including inferior vena cava [Formula: see text] (SBO) and cardiac output (cardiac MRI). Agreement between methods was assessed by interclass correlation coefficients (ICCs), linear regression, and Bland-Altman plots. There was good to excellent agreement between iSTAT and SBO [Formula: see text] for arm exercise (ICC: 0.86, 95% CI: 0.71-0.93, <i>P</i> < 0.01; mean bias: +5.2%). Test-retest reliability demonstrated excellent agreement for [Formula: see text] measures between trials using iSTAT (ICC: 0.97; 95% CI: 0.93-0.96, <i>P</i> < 0.01; mean bias: -2.7%) and SBO (ICC: 0.90, 95% CI: 0.80-0.95, <i>P</i> < 0.01; mean bias: -0.3%), V̇o<sub>2</sub> calculated from MRI<sub>Fick</sub> demonstrated excellent agreement with pulmonary V̇o<sub>2</sub> (ICC: 0.98, 95% CI: 0.97-0.99, <i>P</i> < 0.01; mean bias: +0.10 L/min). MRI-SBO-derived [Formula: see text] measurements demonstrated excellent reliability and strong agreement with both venous measures and respiratory gas analysis, validating this technique across a wide range of [Formula: see text] values during exercise.<b>NEW & NOTEWORTHY</b> Noninvasive MRI susceptometry-based [Formula: see text] measurements demonstrated excellent repeatability and validity against established direct blood sampling during localized handgrip exercise. The technique's accuracy for determining V̇o<sub>2</sub> during step ergometer exercise was validated through strong agreement between combined cardiac MRI and susceptometry-based Fick calculations and reference pulmonary measures, establishing this method as a reliable tool for noninvasive assessment of oxygen uptake and its Fick determinants across varying exercise intensities.

American Journal of Physiology-Heart and Circulatory PhysiologyVol. 328(6)
University of Alberta (CA), The University of Texas at Arlington (US), Universität Innsbruck (AT), University of Saskatchewan (CA), St Vincents Institute of Medical Research (AU)
Alberta Innovates
Clean water and sanitation
Openalex Percentile: Top 4%
Cardiovascular and exercise physiology
7.14
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.