Optimisation of Air-water Harvester Machine Performance With Variations of Inlet Air Flow Velocities

In the dry season, some parts of Indonesia experience drought and clean water crisis which results in scarcity and difficulty in drinking water. One way to overcome this problem is to present a water-producing device from air called a water harvester machine. The purpose of this study was to examine the effect of the inlet air velocity of 4 m/s, 5 m/s, and 6 m/s on the mass of water produced and the rate of heat transfer. This study was conducted experimentally with R134a refrigerant working fluid, and a 1 PK rotary compressor and centrifugal fan. The results showed that the highest water mass, which was 5.99 kg, was obtained at an air velocity of 6 m/s. The highest heat transfer rate, which was 2080.2 W, was also obtained at a speed of 6 m/s. This can be caused by the high inlet air velocity, the inlet air mass flow rate is also high so that the water vapor content that enters is greater. As a result, the mass of water produced is greater and the rate of heat transfer that occurs is also greater.

Authors

Publication Details

Journal
SINTEK JURNAL Jurnal Ilmiah Teknik Mesin
Published
2024-12-01
DOI
https://doi.org/10.24853/sintek.18.2.129-134
Primary Topic
Belt Conveyor Systems Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimisation of Air-water Harvester Machine Performance With Variations of Inlet Air Flow Velocities

Made Wirawan, Mirmanto Mirmanto, Ahmad Tarmisi
SINTEK JURNAL Jurnal Ilmiah Teknik Mesin
Belt Conveyor Systems Engineering
article

Optimisation of Air-water Harvester Machine Performance With Variations of Inlet Air Flow Velocities

Made Wirawan, Mirmanto Mirmanto, Ahmad Tarmisi
article en

Abstract

In the dry season, some parts of Indonesia experience drought and clean water crisis which results in scarcity and difficulty in drinking water. One way to overcome this problem is to present a water-producing device from air called a water harvester machine. The purpose of this study was to examine the effect of the inlet air velocity of 4 m/s, 5 m/s, and 6 m/s on the mass of water produced and the rate of heat transfer. This study was conducted experimentally with R134a refrigerant working fluid, and a 1 PK rotary compressor and centrifugal fan. The results showed that the highest water mass, which was 5.99 kg, was obtained at an air velocity of 6 m/s. The highest heat transfer rate, which was 2080.2 W, was also obtained at a speed of 6 m/s. This can be caused by the high inlet air velocity, the inlet air mass flow rate is also high so that the water vapor content that enters is greater. As a result, the mass of water produced is greater and the rate of heat transfer that occurs is also greater.

SINTEK JURNAL Jurnal Ilmiah Teknik MesinVol. 18(2)
Openalex Percentile: Top 71%
Belt Conveyor Systems Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.