Capacitance compensation on a double-barrel nanopipette for improving current detection of scanning ion conductance microscopy

We developed a method to improve the current-detection response of scanning ion conduction microscopy (SICM) using a double-barrel nanopipette. By detecting the difference between the two signals from each channel, capacitive currents can be canceled out, resulting in an improved ion current detection response and reduced imaging time in bias-modulated scanning ion conductance microscopy operated with AC bias voltages (BM-SICM). Furthermore, this method can reduce the synchronized capacitive current noise of two adjacent channels of a double-barrel nanopipette by canceling each other via a differential operation. Therefore, an improved detection signal was achieved even in the SICM operated with a DC bias voltage by reducing the noise from the piezoelectric scanner. As demonstrated by the proposed method, chromosomes that were difficult to observe owing to their strong negative charges were clearly imaged in the BM-SICM operated with an AC bias voltage without artifacts caused by surface charging. Additionally, in SICM operating with a DC bias voltage, dynamic interaction among an intracellular short rod, Listeria monocytogenes, and Caco-2 human enterocyte-like cells was successfully observed.

Authors

Institutions

Publication Details

Journal
Ultramicroscopy
Published
2025-04-18
DOI
https://doi.org/10.1016/j.ultramic.2025.114149
Citations
1
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
0.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Capacitance compensation on a double-barrel nanopipette for improving current detection of scanning ion conductance microscopy

Toshi Nagata, Hideya Kawasaki, Naoto Fukuzawa, Kenta Nakazawa et al.
1 citations
Ultramicroscopy
Electrochemical Analysis and Applications
0.52
article

Capacitance compensation on a double-barrel nanopipette for improving current detection of scanning ion conductance microscopy

Toshi Nagata, Hideya Kawasaki, Naoto Fukuzawa, Kenta Nakazawa, H Inomata, Futoshi Iwata, Osamu Hoshi
article en
1 citations

Abstract

We developed a method to improve the current-detection response of scanning ion conduction microscopy (SICM) using a double-barrel nanopipette. By detecting the difference between the two signals from each channel, capacitive currents can be canceled out, resulting in an improved ion current detection response and reduced imaging time in bias-modulated scanning ion conductance microscopy operated with AC bias voltages (BM-SICM). Furthermore, this method can reduce the synchronized capacitive current noise of two adjacent channels of a double-barrel nanopipette by canceling each other via a differential operation. Therefore, an improved detection signal was achieved even in the SICM operated with a DC bias voltage by reducing the noise from the piezoelectric scanner. As demonstrated by the proposed method, chromosomes that were difficult to observe owing to their strong negative charges were clearly imaged in the BM-SICM operated with an AC bias voltage without artifacts caused by surface charging. Additionally, in SICM operating with a DC bias voltage, dynamic interaction among an intracellular short rod, Listeria monocytogenes, and Caco-2 human enterocyte-like cells was successfully observed.

UltramicroscopyVol. 273
Tokyo Medical and Dental University (JP), Shizuoka University (JP), Hamamatsu University School of Medicine (JP)
Nakatani Foundation for Advancement of Measuring Technologies in Biomedical Engineering, Japan Society for the Promotion of Science
Affordable and clean energy
Openalex Percentile: Top 45%
Electrochemical Analysis and Applications
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.