Research on reactive power configuration of offshore wind power transmission system through power frequency AC transmission

The large charging power of submarine cables leads to severe power frequency overvoltage in offshore wind power(OWP) transmission systems, and high-voltage parallel reactors can be used to limit it. The article takes a 500kV OW farm in China as an example to theoretically calculate its power frequency overvoltage. Using the electromagnetic transient program (ATP EMTP), a model of the OW farm's AC submarine cable (SC) transmission system was established, and the distribution of power frequency overvoltage in the transmission system was calculated. The configuration scheme of high-voltage parallel reactors was analyzed. Research has shown that the system side load rejection overvoltage is much greater than the wind farm side load rejection overvoltage; When the total compensation is the same, the effect of single end compensation on land is slightly better than that of dual end compensation. On this basis, a high-voltage parallel reactor configuration scheme for the power frequency overvoltage limitation of the OW farm was provided, providing technical basis for engineering design and equipment selection.

Authors

Institutions

Publication Details

Published
2025-04-18
DOI
https://doi.org/10.1117/12.3065334
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on reactive power configuration of offshore wind power transmission system through power frequency AC transmission

Libang Guo, Hai Yu
HVDC Systems and Fault Protection
article

Research on reactive power configuration of offshore wind power transmission system through power frequency AC transmission

Libang Guo, Hai Yu
article en

Abstract

The large charging power of submarine cables leads to severe power frequency overvoltage in offshore wind power(OWP) transmission systems, and high-voltage parallel reactors can be used to limit it. The article takes a 500kV OW farm in China as an example to theoretically calculate its power frequency overvoltage. Using the electromagnetic transient program (ATP EMTP), a model of the OW farm's AC submarine cable (SC) transmission system was established, and the distribution of power frequency overvoltage in the transmission system was calculated. The configuration scheme of high-voltage parallel reactors was analyzed. Research has shown that the system side load rejection overvoltage is much greater than the wind farm side load rejection overvoltage; When the total compensation is the same, the effect of single end compensation on land is slightly better than that of dual end compensation. On this basis, a high-voltage parallel reactor configuration scheme for the power frequency overvoltage limitation of the OW farm was provided, providing technical basis for engineering design and equipment selection.

Energy Research Institute (CN)
Affordable and clean energy
Openalex Percentile: Top 94%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on reactive power configuration of offshore wind power transmission system through power frequency AC transmission — Libang Guo, Hai Yu · (2025) | TGRS Research Map | TGRS