Numerical analysis of a SiN digital Fourier transform spectrometer for a non-invasive glucose monitor

We performed numerical analysis on an integrated digital Fourier transform interferometer operating on a silicon-nitride platform. This device acquires Raman spectra through a switch-based digital Fourier transform spectrometer, employing a single optical power meter for detection. Using a standard regularized regression method, we successfully reconstructed a typical Raman skin spectrum in the range of 800<i>c</i><i>m</i><sup>-1</sup> to 1800<i>c</i><i>m</i><sup>-1</sup>. Additionally, we varied the intensity of the Raman peak at 1125<i>c</i><i>m</i><sup>-1</sup>, corresponding to a characteristic glucose signature, and determined a minimal sensitivity threshold of <i>Δ</i><i>P</i>=0.509<i>n</i><i>W</i>.

Authors

Publication Details

Journal
Applied Optics
Published
2025-04-18
DOI
https://doi.org/10.1364/ao.559075
Citations
1
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
1.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical analysis of a SiN digital Fourier transform spectrometer for a non-invasive glucose monitor

Gerardo Castañón, M. Blanco
1 citations
Applied Optics
Spectroscopy Techniques in Biomedical and Chemical Research
1.63
article

Numerical analysis of a SiN digital Fourier transform spectrometer for a non-invasive glucose monitor

Gerardo Castañón, M. Blanco
article en
1 citations

Abstract

We performed numerical analysis on an integrated digital Fourier transform interferometer operating on a silicon-nitride platform. This device acquires Raman spectra through a switch-based digital Fourier transform spectrometer, employing a single optical power meter for detection. Using a standard regularized regression method, we successfully reconstructed a typical Raman skin spectrum in the range of 800<i>c</i><i>m</i><sup>-1</sup> to 1800<i>c</i><i>m</i><sup>-1</sup>. Additionally, we varied the intensity of the Raman peak at 1125<i>c</i><i>m</i><sup>-1</sup>, corresponding to a characteristic glucose signature, and determined a minimal sensitivity threshold of <i>Δ</i><i>P</i>=0.509<i>n</i><i>W</i>.

Applied OpticsVol. 64(14)
Zero hunger
Openalex Percentile: Top 15%
Spectroscopy Techniques in Biomedical and Chemical Research
1.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.