Investigation on a direct expansion multisource carbon dioxide heat pump to maximize the use of renewable energy sources

Traditional heat pump systems typically rely on a single low-temperature source, such as air, ground, or solar energy, each with intrinsic limitations. Air-source heat pumps are highly sensitive to temperature fluctuations across seasons and daily cycles, while the efficiency of solar-source heat pumps is constrained by the intermittent availability of solar radiation. Ground-source heat pumps, in contrast, deliver consistent seasonal performance but involve higher costs for the installation of borehole heat exchangers. Multisource heat pumps offer a promising technology to overcome these challenges and maximize the use of renewable energy. This paper presents a numerical investigation of an innovative multisource heat pump using CO2 as a low GWP refrigerant, that can exploit three different thermal sources through dedicated evaporators: air source with a finned coil heat exchanger, solar source with photovoltaic-thermal (PV-T) collectors, and ground source with a U-tube borehole heat exchanger (BHE). Two modes of operation are foreseen: solar-air mode (SA-mode) and ground-air mode (GA-mode). The novelty of this system lies in the concept of a multisource direct expansion heat pump in which the CO2 directly vaporizes in flooded mode in the solar or ground evaporators, while the finned coil works in dry expansion mode. Differently from all other systems, the solar and ground evaporators operate simultaneously with the air evaporator. Simulations are performed to assess the performance of the multisource heat pump under varying environmental conditions: air temperature, solar irradiance, and soil temperature. The results demonstrate that while air temperature influences the performance of both SA-mode and GA-mode, each mode exhibits distinct sensitivities to the other environmental parameters. SA-mode performance is significantly affected by solar irradiance, with a 100 W/m2 increase in irradiance corresponding to a 2.8 % enhancement in the coefficient of performance (COP). Conversely, GA-mode performance shows a notable response to soil temperature variations, where a 1 K increase in soil temperature results in a 0.9 % improvement in COP. The results compare SA-mode and GA-mode with air-source heat pump mode under varying thermal loads for space heating (SH) and domestic hot water (DHW) production, showing up to 22 % COP increase for GA-mode and SA-mode. As a further step, the study investigates the effect of varying the number of PV-T modules and borehole heat exchangers on the heat pump performance. The simultaneous use of two energy sources always results in improved system performance even with limited PV-T or BHE heat transfer areas.

Authors

Publication Details

Journal
Applied Thermal Engineering
Published
2025-04-18
DOI
https://doi.org/10.1016/j.applthermaleng.2025.126533
Citations
5
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
3.57

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation on a direct expansion multisource carbon dioxide heat pump to maximize the use of renewable energy sources

Emanuele Zanetti, Marco Azzolin, Davide Del Col, Marco Tancon et al.
5 citations
Applied Thermal Engineering
Refrigeration and Air Conditioning Technologies
3.57
article

Investigation on a direct expansion multisource carbon dioxide heat pump to maximize the use of renewable energy sources

Emanuele Zanetti, Marco Azzolin, Davide Del Col, Marco Tancon, Riccardo Conte, Mohammad Mozafarivanani
article en
5 citations

Abstract

Traditional heat pump systems typically rely on a single low-temperature source, such as air, ground, or solar energy, each with intrinsic limitations. Air-source heat pumps are highly sensitive to temperature fluctuations across seasons and daily cycles, while the efficiency of solar-source heat pumps is constrained by the intermittent availability of solar radiation. Ground-source heat pumps, in contrast, deliver consistent seasonal performance but involve higher costs for the installation of borehole heat exchangers. Multisource heat pumps offer a promising technology to overcome these challenges and maximize the use of renewable energy. This paper presents a numerical investigation of an innovative multisource heat pump using CO2 as a low GWP refrigerant, that can exploit three different thermal sources through dedicated evaporators: air source with a finned coil heat exchanger, solar source with photovoltaic-thermal (PV-T) collectors, and ground source with a U-tube borehole heat exchanger (BHE). Two modes of operation are foreseen: solar-air mode (SA-mode) and ground-air mode (GA-mode). The novelty of this system lies in the concept of a multisource direct expansion heat pump in which the CO2 directly vaporizes in flooded mode in the solar or ground evaporators, while the finned coil works in dry expansion mode. Differently from all other systems, the solar and ground evaporators operate simultaneously with the air evaporator. Simulations are performed to assess the performance of the multisource heat pump under varying environmental conditions: air temperature, solar irradiance, and soil temperature. The results demonstrate that while air temperature influences the performance of both SA-mode and GA-mode, each mode exhibits distinct sensitivities to the other environmental parameters. SA-mode performance is significantly affected by solar irradiance, with a 100 W/m2 increase in irradiance corresponding to a 2.8 % enhancement in the coefficient of performance (COP). Conversely, GA-mode performance shows a notable response to soil temperature variations, where a 1 K increase in soil temperature results in a 0.9 % improvement in COP. The results compare SA-mode and GA-mode with air-source heat pump mode under varying thermal loads for space heating (SH) and domestic hot water (DHW) production, showing up to 22 % COP increase for GA-mode and SA-mode. As a further step, the study investigates the effect of varying the number of PV-T modules and borehole heat exchangers on the heat pump performance. The simultaneous use of two energy sources always results in improved system performance even with limited PV-T or BHE heat transfer areas.

Applied Thermal EngineeringVol. 274
European Commission
Affordable and clean energy
Openalex Percentile: Top 8%
Refrigeration and Air Conditioning Technologies
3.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.