Effect of Preoperative Dry Eye Treatment with Intense Pulsed Light with Meibomian Gland Expression on the Refractive Accuracy of Cataract Surgery in Patients with Meibomian Gland Dysfunction-Related Dry Eye: A Single-Center, Prospective, Open-Label S

<b>Objective:</b> This research seeks to investigate the effects of preoperative intense pulsed light with manual meibomian expression (IPL-MGX) on the refractive accuracy of cataract surgery on dry eyes with meibomian gland dysfunction (MGD-related dry eyes). <b>Methods:</b> Fifty-six MGD-related dry eye cases planned for cataract surgery were analyzed. IPL-MGX (four times at 2-week intervals) was performed before preoperative examination. Axial length (AL), anterior chamber depth (ACD), corneal curvature (mean-K), tear break-up time (TBUT), superficial punctate keratopathy in the central cornea (C-SPK), corneal higher-order aberrations (HOAs), and predicted postoperative spherical equivalent (P-SE) were evaluated pre- and post-IPL-MGX. The postoperative subjective spherical equivalent (S-SE) was evaluated after one month. The absolute difference between the S-SE and P-SE was considered an indication of P-SE accuracy. Changes in all the variables were assessed before and after IPL-MGX treatment. <b>Results:</b> No significant differences were observed in AL or ACD (<i>p</i> = 0.85, 0.56). The differences in mean-K, TBUT, C-SPK, and HOAs were significant (<i>p</i> < 0.01). P-SE accuracy based on post-IPL-MGX data was significantly higher than that based on pre-IPL-MGX data (<i>p</i> < 0.01). P-SE accuracy was within 0.25 diopters (D) in 14.3% of pre- and 55.4% of post-IPL-MGX, within 0.5D in 55.4% of pre- and 92.9% of post-IPL-MGX, within 0.75D in 98.2% of pre- and post-IPL-MGX, and within 1.0D in 98.2% of pre- and 100% of post-IPL-MGX. In the range of 0.25 and 0.5 D, the accuracy of P-SE was significantly higher in post-IPL-MGX (<i>p</i> < 0.01). <b>Conclusions:</b> Preoperative IPL-MGX considerably improved the predicted postoperative refraction accuracy in patients with MGD-related dry eye undergoing cataract surgery.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-04-18
DOI
https://doi.org/10.3390/jcm14082805
Citations
8
Primary Topic
Ocular Surface and Contact Lens
Type
article
Field-Weighted Citation Impact
15.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Preoperative Dry Eye Treatment with Intense Pulsed Light with Meibomian Gland Expression on the Refractive Accuracy of Cataract Surgery in Patients with Meibomian Gland Dysfunction-Related Dry Eye: A Single-Center, Prospective, Open-Label S

Seiichiro Hata, Kazuro Yabuki, Nobuhisa Mizuki, Tatsukata Kawagoe et al.
8 citations
Journal of Clinical Medicine
Ocular Surface and Contact Lens
15.03
article

Effect of Preoperative Dry Eye Treatment with Intense Pulsed Light with Meibomian Gland Expression on the Refractive Accuracy of Cataract Surgery in Patients with Meibomian Gland Dysfunction-Related Dry Eye: A Single-Center, Prospective, Open-Label S

Seiichiro Hata, Kazuro Yabuki, Nobuhisa Mizuki, Tatsukata Kawagoe, Masaki Takeuchi, Yuki Mizuki, Miki Akaishi, Takeshi Teshigawara, Akira Meguro
article en
8 citations

Abstract

<b>Objective:</b> This research seeks to investigate the effects of preoperative intense pulsed light with manual meibomian expression (IPL-MGX) on the refractive accuracy of cataract surgery on dry eyes with meibomian gland dysfunction (MGD-related dry eyes). <b>Methods:</b> Fifty-six MGD-related dry eye cases planned for cataract surgery were analyzed. IPL-MGX (four times at 2-week intervals) was performed before preoperative examination. Axial length (AL), anterior chamber depth (ACD), corneal curvature (mean-K), tear break-up time (TBUT), superficial punctate keratopathy in the central cornea (C-SPK), corneal higher-order aberrations (HOAs), and predicted postoperative spherical equivalent (P-SE) were evaluated pre- and post-IPL-MGX. The postoperative subjective spherical equivalent (S-SE) was evaluated after one month. The absolute difference between the S-SE and P-SE was considered an indication of P-SE accuracy. Changes in all the variables were assessed before and after IPL-MGX treatment. <b>Results:</b> No significant differences were observed in AL or ACD (<i>p</i> = 0.85, 0.56). The differences in mean-K, TBUT, C-SPK, and HOAs were significant (<i>p</i> < 0.01). P-SE accuracy based on post-IPL-MGX data was significantly higher than that based on pre-IPL-MGX data (<i>p</i> < 0.01). P-SE accuracy was within 0.25 diopters (D) in 14.3% of pre- and 55.4% of post-IPL-MGX, within 0.5D in 55.4% of pre- and 92.9% of post-IPL-MGX, within 0.75D in 98.2% of pre- and post-IPL-MGX, and within 1.0D in 98.2% of pre- and 100% of post-IPL-MGX. In the range of 0.25 and 0.5 D, the accuracy of P-SE was significantly higher in post-IPL-MGX (<i>p</i> < 0.01). <b>Conclusions:</b> Preoperative IPL-MGX considerably improved the predicted postoperative refraction accuracy in patients with MGD-related dry eye undergoing cataract surgery.

Journal of Clinical MedicineVol. 14(8)
Minamiaoyama Eye Clinic (JP), Saiseikai Ibaraki Hospital (JP), Yokohama City University (JP)
Good health and well-being
Openalex Percentile: Top 1%
Ocular Surface and Contact Lens
15.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.