Automatication of Thickness Slice Measurement Using Non-Rotation Method on Three Ladder Objects from Computed Tomography

To perform slice thickness calculation automatically using the non-rotational method on the three ladder objects in the AAPM CT Performance Phantom image. Phantom was scanned with a GE Healthcare 128-slice CT scan scanner using slice thicknesses of 0.625 mm, 5.0 mm, and 10.0 mm. The software was developed with a non- rotational method to be able to measure the FWHM value and the mean on the three rungs of the object. In addition, the FWHM of the non-rotational method was compared with the rotational method The FWHM value from automatic measurement for slice thickness is 0.625 mm in three slice variations with non-rotational method 1.68 mm and rotation method 1.61 mm while for slice thickness 5.0 mm on non-rotation method is 6.51 mm, rotation method is 6.68 mm. , and for a slice thickness of 10.0 mm for the non-rotational method 9.58 mm and the rotational method 9.75 mm. The results of the non-rotational method were slightly lower (i.e. 1,74%) than the results of the rotational method for each nominal slice thickness, except for the smallest slicethickness The automatic slice thickness measurement algorithm on AAPM CT Performance Phantom has been improved using a non-rotational method. The improved algorithm can overcome the widening problem that occurred in the previous method due to object rotation.

Authors

Institutions

Publication Details

Journal
Jurnal Penelitian Pendidikan IPA
Published
2025-03-25
DOI
https://doi.org/10.29303/jppipa.v11i3.9978
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automatication of Thickness Slice Measurement Using Non-Rotation Method on Three Ladder Objects from Computed Tomography

Hasia Marto, Dewi Angraini Insiano
Jurnal Penelitian Pendidikan IPA
Medical Imaging Techniques and Applications
article

Automatication of Thickness Slice Measurement Using Non-Rotation Method on Three Ladder Objects from Computed Tomography

Hasia Marto, Dewi Angraini Insiano
article en

Abstract

To perform slice thickness calculation automatically using the non-rotational method on the three ladder objects in the AAPM CT Performance Phantom image. Phantom was scanned with a GE Healthcare 128-slice CT scan scanner using slice thicknesses of 0.625 mm, 5.0 mm, and 10.0 mm. The software was developed with a non- rotational method to be able to measure the FWHM value and the mean on the three rungs of the object. In addition, the FWHM of the non-rotational method was compared with the rotational method The FWHM value from automatic measurement for slice thickness is 0.625 mm in three slice variations with non-rotational method 1.68 mm and rotation method 1.61 mm while for slice thickness 5.0 mm on non-rotation method is 6.51 mm, rotation method is 6.68 mm. , and for a slice thickness of 10.0 mm for the non-rotational method 9.58 mm and the rotational method 9.75 mm. The results of the non-rotational method were slightly lower (i.e. 1,74%) than the results of the rotational method for each nominal slice thickness, except for the smallest slicethickness The automatic slice thickness measurement algorithm on AAPM CT Performance Phantom has been improved using a non-rotational method. The improved algorithm can overcome the widening problem that occurred in the previous method due to object rotation.

Jurnal Penelitian Pendidikan IPAVol. 11(3)
University of Toledo (US)
Openalex Percentile: Top 88%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.