Introducing bimetallic MOF-based electrochemical sensor for voltametric nanogram determination of sulfadimidine: various applications and a comprehensive sustainability assessment

Due to its characteristics and allowable use, the sulphonamide group remains a first-choice treatment for veterinarians when managing multiple veterinary diseases. Unfortunately, long-term consumption of food containing sulphonamide residues can result in harmful effects, especially that sulphonamides are classified in category D. Metal-organic frameworks (MOFs) have demonstrated outstanding selectivity in detecting target components due to their large surface areas and intricate structures. In this study, we present a novel voltammetric approach for determining sulfadimidine (SLD) in veterinary formulations, animal plasma, and animal-derived products, including milk and eggs. We employed a bimetallic Cu/Ni-MOF to modify a carbon paste electrode, utilizing differential pulse voltammetry (DPV) for SLD detection. The morphology of the Cu/Ni-MOF was analyzed to ensure optimal structural characteristics, and experimental conditions were optimized to achieve the best performance. A major advantage of this method is its wide linearity range (100 nM to 100,000 nM) and the ability to detect SLD at nanogram levels, with a LOD of 20 nM and a LOQ of 60 nM. These characteristics demonstrate the fabricated Cu/Ni-MOF's capability to detect SLD at levels below its maximum residue limit (MRL) in plasma, milk, and eggs. Furthermore, the environmental impact of this method was assessed using the RGB 12 metric and compared against the AGREE, Complex GAPI, and BAGI metrics, offering a comprehensive evaluation of its analytical performance and practical advantages. This approach holds promise for curbing antibiotic misuse by providing a straightforward and effective method for SLD detection across multiple matrices.

Authors

Institutions

Publication Details

Journal
BMC Chemistry
Published
2025-04-18
DOI
https://doi.org/10.1186/s13065-025-01465-7
Citations
3
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
2.26

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Introducing bimetallic MOF-based electrochemical sensor for voltametric nanogram determination of sulfadimidine: various applications and a comprehensive sustainability assessment

Hind A Abdullatif, M. A. Abdelkawy, Nesma Mahmoud Fahmy, Shereen A. Boltia et al.
3 citations
BMC Chemistry
Analytical chemistry methods development
2.26
article

Introducing bimetallic MOF-based electrochemical sensor for voltametric nanogram determination of sulfadimidine: various applications and a comprehensive sustainability assessment

Hind A Abdullatif, M. A. Abdelkawy, Nesma Mahmoud Fahmy, Shereen A. Boltia, Maha Kamal
article en
3 citations

Abstract

Due to its characteristics and allowable use, the sulphonamide group remains a first-choice treatment for veterinarians when managing multiple veterinary diseases. Unfortunately, long-term consumption of food containing sulphonamide residues can result in harmful effects, especially that sulphonamides are classified in category D. Metal-organic frameworks (MOFs) have demonstrated outstanding selectivity in detecting target components due to their large surface areas and intricate structures. In this study, we present a novel voltammetric approach for determining sulfadimidine (SLD) in veterinary formulations, animal plasma, and animal-derived products, including milk and eggs. We employed a bimetallic Cu/Ni-MOF to modify a carbon paste electrode, utilizing differential pulse voltammetry (DPV) for SLD detection. The morphology of the Cu/Ni-MOF was analyzed to ensure optimal structural characteristics, and experimental conditions were optimized to achieve the best performance. A major advantage of this method is its wide linearity range (100 nM to 100,000 nM) and the ability to detect SLD at nanogram levels, with a LOD of 20 nM and a LOQ of 60 nM. These characteristics demonstrate the fabricated Cu/Ni-MOF's capability to detect SLD at levels below its maximum residue limit (MRL) in plasma, milk, and eggs. Furthermore, the environmental impact of this method was assessed using the RGB 12 metric and compared against the AGREE, Complex GAPI, and BAGI metrics, offering a comprehensive evaluation of its analytical performance and practical advantages. This approach holds promise for curbing antibiotic misuse by providing a straightforward and effective method for SLD detection across multiple matrices.

BMC ChemistryVol. 19(1)
Cairo University (EG), Ahram Canadian University (EG)
Cairo University, Science and Technology Development Fund
Responsible consumption and production
Openalex Percentile: Top 14%
Analytical chemistry methods development
2.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.