Vibration testing of mechanical resilience of bolometer sensors and sensor holders under ITER-relevant conditions

The ITER bolometer diagnostic will provide the measurement of the total radiation emitted from the plasma, a part of the overall energy balance. Up to 550 sensor channels will be installed in ITER in 71 cameras of various sizes and types. The sensor holder is the component inside those cameras to provide attachment and signal connections to the sensor itself. A design of a sensor holder has been proposed previously based on ceramic front and back plates with wire bonded contacts to the sensor and welded signal cables. This concept can provide the reliable electrical connections required for ITER at temperatures up to 350 ° C and had been prototyped and proven to be manufacturable. In order to verify its resilience against mechanical loads as well as that of the sensors, sensor holder assemblies have been subjected to accelerations on a shaking table. The magnitude of the accelerations applied (up to 625 m s 2 in the frequency range from 5 Hz up to 1 kHz) have been deduced based on load definitions from ITER describing the floor response spectra for typical seismic events as well as the ones expected during disruptions due to electro-magnetically induced forces in bolometer cameras and port structures within which they are mounted. A particular focus has been placed on testing whether it is beneficial to cover the bond wires with a ceramic paste to protect them against fatigue breaks due to vibrations. The tests demonstrated that the chosen sensor assembly is well capable of withstanding all applied loads without failures and thus demonstrating its structural integrity during the expected operations. Within the limited number of load cycles no need to apply the ceramic paste could be identified.

Authors

Institutions

Publication Details

Journal
Fusion Engineering and Design
Published
2025-04-18
DOI
https://doi.org/10.1016/j.fusengdes.2025.115042
Primary Topic
Structural Health Monitoring Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vibration testing of mechanical resilience of bolometer sensors and sensor holders under ITER-relevant conditions

L. C. Ingesson, U. Walach, N. Medrano, Á. Pataki et al.
Fusion Engineering and Design
Structural Health Monitoring Techniques
article

Vibration testing of mechanical resilience of bolometer sensors and sensor holders under ITER-relevant conditions

L. C. Ingesson, U. Walach, N. Medrano, Á. Pataki, H. Meister
article en

Abstract

The ITER bolometer diagnostic will provide the measurement of the total radiation emitted from the plasma, a part of the overall energy balance. Up to 550 sensor channels will be installed in ITER in 71 cameras of various sizes and types. The sensor holder is the component inside those cameras to provide attachment and signal connections to the sensor itself. A design of a sensor holder has been proposed previously based on ceramic front and back plates with wire bonded contacts to the sensor and welded signal cables. This concept can provide the reliable electrical connections required for ITER at temperatures up to 350 ° C and had been prototyped and proven to be manufacturable. In order to verify its resilience against mechanical loads as well as that of the sensors, sensor holder assemblies have been subjected to accelerations on a shaking table. The magnitude of the accelerations applied (up to 625 m s 2 in the frequency range from 5 Hz up to 1 kHz) have been deduced based on load definitions from ITER describing the floor response spectra for typical seismic events as well as the ones expected during disruptions due to electro-magnetically induced forces in bolometer cameras and port structures within which they are mounted. A particular focus has been placed on testing whether it is beneficial to cover the bond wires with a ceramic paste to protect them against fatigue breaks due to vibrations. The tests demonstrated that the chosen sensor assembly is well capable of withstanding all applied loads without failures and thus demonstrating its structural integrity during the expected operations. Within the limited number of load cycles no need to apply the ceramic paste could be identified.

Fusion Engineering and DesignVol. 216
Universidade Politécnica de Castelo Branco (PT), Max Planck Institute for Plasma Physics (DE), Fusion for Energy (ES)
Fusion for Energy
Openalex Percentile: Top 92%
Structural Health Monitoring Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.