The Design of a Core Biopsy Needle with a Larger Sample Extraction Size

Acquiring core biopsy samples requires a minimally invasive procedure in which tissue samples are collected from internal organs for histologic diagnosis. Usually, a clinician requests and extracts core biopsy samples when there is a suspicious lump in the body. Samples are used to diagnose various forms of cancer and other diseases. However, to have enough sample size to perform histological tests, clinicians must insert/extract the core biopsy needle a couple of times. These multiple insertions/extractions might reduce the healing process and increase the patient’s risk of infection, internal organ damage, and unwanted bleeding. To address such an issue, it is recommended to obtain the required amount of tissue sample in a single insertion/extraction. In this study, a 14-gauge core biopsy needle (CBN) design, with four sample notches, was designed instead of the conventional one-sample notch to maximize the size of the sample being collected. Furthermore, sample notches were redesigned in a plus (+) cross-sectional pattern to improve the overall strength of the core biopsy needle at the sample notch area. This plus-shaped design of the sample notch enables the decrease of the thickness of the metal the biopsy needle is made from, increasing the sample notch size and thus increasing the total sample size extracted. In this design, each sample notch can collect 13.14 mm3 of sample. Hence, with four sample notches, the total sample being collected is 52.56 mm3 compared to conventional CBNs that can collect a sample size of 30.94 mm3 only. A significant increase of up to 69.88% in the sample size being collected was calculated compared to 14-gauge conventional CBNs, such as Achieve® biopsy needles.

Authors

Institutions

Publication Details

Journal
International Journal of Online and Biomedical Engineering (iJOE)
Published
2025-04-18
DOI
https://doi.org/10.3991/ijoe.v21i05.53817
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Design of a Core Biopsy Needle with a Larger Sample Extraction Size

Abdulaziz S. Fakhouri
International Journal of Online and Biomedical Engineering (iJOE)
Radiomics and Machine Learning in Medical Imaging
article

The Design of a Core Biopsy Needle with a Larger Sample Extraction Size

Abdulaziz S. Fakhouri
article en

Abstract

Acquiring core biopsy samples requires a minimally invasive procedure in which tissue samples are collected from internal organs for histologic diagnosis. Usually, a clinician requests and extracts core biopsy samples when there is a suspicious lump in the body. Samples are used to diagnose various forms of cancer and other diseases. However, to have enough sample size to perform histological tests, clinicians must insert/extract the core biopsy needle a couple of times. These multiple insertions/extractions might reduce the healing process and increase the patient’s risk of infection, internal organ damage, and unwanted bleeding. To address such an issue, it is recommended to obtain the required amount of tissue sample in a single insertion/extraction. In this study, a 14-gauge core biopsy needle (CBN) design, with four sample notches, was designed instead of the conventional one-sample notch to maximize the size of the sample being collected. Furthermore, sample notches were redesigned in a plus (+) cross-sectional pattern to improve the overall strength of the core biopsy needle at the sample notch area. This plus-shaped design of the sample notch enables the decrease of the thickness of the metal the biopsy needle is made from, increasing the sample notch size and thus increasing the total sample size extracted. In this design, each sample notch can collect 13.14 mm3 of sample. Hence, with four sample notches, the total sample being collected is 52.56 mm3 compared to conventional CBNs that can collect a sample size of 30.94 mm3 only. A significant increase of up to 69.88% in the sample size being collected was calculated compared to 14-gauge conventional CBNs, such as Achieve® biopsy needles.

International Journal of Online and Biomedical Engineering (iJOE)Vol. 21(05)
King Saud University (SA)
King Saud University
Openalex Percentile: Top 88%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.