Visual Results After Extended Depth-of-Focus Lens Implantation in Patients Undergoing Clear Lens Surgery

<b>Background/Objectives</b>: To evaluate the efficacy and visual quality provided by the extended depth-of-focus AcrySof IQ Vivity lens (Alcon Laboratories, Inc., Fort Worth, TX, USA) in patients undergoing refractive lens exchange (RLE) surgery for presbyopia correction. <b>Methods</b>: This descriptive prospective single-arm clinical study included 30 patients (60 eyes) aged 49-69 years (mean 60.2) who underwent clear lens surgery for presbyopia correction. Postoperative 3-month assessments included uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), distance-corrected intermediate visual acuity (DCIVA), and distance-corrected near visual acuity (DCNVA) measurements. Patient satisfaction and visual disturbances were evaluated using a standardized questionnaire. <b>Results</b>: Postoperative binocular visual acuity results were as follows: UDVA, 0.00 ± 0.06 logMAR; UIVA 0.08 ± 0.07 logMAR; and UNVA, 0.18 ± 0.10 logMAR. Refractive outcomes showed mean spherical equivalent values of -0.15 D ± 0.28 diopters (D) for the right eye and -0.18 D ± 0.30 D for the left eye postoperatively. Most patients (93.2%) were satisfied or very satisfied with the surgery, and 63.3% never needed glasses at any distance postoperatively. Mild and non-disabling photic phenomena were reported by 23% of patients for halos and 30% for glares. <b>Conclusions</b>: The study IOL provides excellent visual acuity for far and intermediate distances, as well as functional near vision under photopic conditions, with high levels of patient satisfaction and minimal visual disturbances. This lens is a promising option for non-cataract patients undergoing RLE for presbyopia correction.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-04-18
DOI
https://doi.org/10.3390/jcm14082795
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Visual Results After Extended Depth-of-Focus Lens Implantation in Patients Undergoing Clear Lens Surgery

Nuria Garzón, Miguel Ángel Sánchez‐Tena, Felipe Couñago, Emanuel Barberá-Loustaunau
Journal of Clinical Medicine
Ophthalmology and Visual Impairment Studies
article

Visual Results After Extended Depth-of-Focus Lens Implantation in Patients Undergoing Clear Lens Surgery

Nuria Garzón, Miguel Ángel Sánchez‐Tena, Felipe Couñago, Emanuel Barberá-Loustaunau
article en

Abstract

<b>Background/Objectives</b>: To evaluate the efficacy and visual quality provided by the extended depth-of-focus AcrySof IQ Vivity lens (Alcon Laboratories, Inc., Fort Worth, TX, USA) in patients undergoing refractive lens exchange (RLE) surgery for presbyopia correction. <b>Methods</b>: This descriptive prospective single-arm clinical study included 30 patients (60 eyes) aged 49-69 years (mean 60.2) who underwent clear lens surgery for presbyopia correction. Postoperative 3-month assessments included uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), distance-corrected intermediate visual acuity (DCIVA), and distance-corrected near visual acuity (DCNVA) measurements. Patient satisfaction and visual disturbances were evaluated using a standardized questionnaire. <b>Results</b>: Postoperative binocular visual acuity results were as follows: UDVA, 0.00 ± 0.06 logMAR; UIVA 0.08 ± 0.07 logMAR; and UNVA, 0.18 ± 0.10 logMAR. Refractive outcomes showed mean spherical equivalent values of -0.15 D ± 0.28 diopters (D) for the right eye and -0.18 D ± 0.30 D for the left eye postoperatively. Most patients (93.2%) were satisfied or very satisfied with the surgery, and 63.3% never needed glasses at any distance postoperatively. Mild and non-disabling photic phenomena were reported by 23% of patients for halos and 30% for glares. <b>Conclusions</b>: The study IOL provides excellent visual acuity for far and intermediate distances, as well as functional near vision under photopic conditions, with high levels of patient satisfaction and minimal visual disturbances. This lens is a promising option for non-cataract patients undergoing RLE for presbyopia correction.

Journal of Clinical MedicineVol. 14(8)
Universidad Complutense de Madrid (ES), Hospital Quirónsalud Barcelona (ES), Universidad Europea de Madrid (ES)
Quality Education
Openalex Percentile: Top 88%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.