Ultra-sensitive determination of Zn, Cd, Ni, Cu, and Pb in high salt matrix water samples using solid phase extraction coupled with solution cathode glow discharge atomic emission spectrometry

• Multiple heavy metals were simultaneous detected using SCGD-AES coupled with SPE . • The tolerance of SPE-SCGD-AES against the salt matrix could reach up to 10000 mg/L. • The DLs of Zn, Cd, Ni, Cu, and Pb were 1, 0.6, 2, 0.6, and 6 μg/L. Herein, we developed a highly sensitive method based on solution cathode glow discharge atomic emission spectrometry (SCGD-AES) coupled with solid-phase extraction (SPE) for the determination of Zn, Cd, Ni, Cu, and Pb in high salt matrix water samples. The trace metals were collected from 100 mL water which was adjusted the pH to 4–10 (this step was unnecessary for most environmental water samples due to their inherent pH compatibility) using a column (i.d. = 6.6 mm) of a chelating resin (bed height = 7.2 cm) and eluted with 5 mL 1 M HNO 3 at a flow rate of 3 mL/min. At the same time, the pH of the eluate would be adjust from 0 to 0.9 (a suitable acidity for SCGD) by the resin column. Then the heavy metals in elute were detected by SCGD with constant current mode. When 100 mL sample water was enriched, the detection limits of Zn, Cd, Ni, Cu, and Pb were 1, 0.6, 2, 0.6, and 6 μg/ L which were improved by almost 20 times. And the tolerance of SCGD for Cd, Cu, Ni, Pb, and Zn detection against the salt matrix (exemplified by Na) could reach up to 10000 mg/L. The method’s accuracy and practicality were validated through successful application to environmental water samples, high salt matrix simulated water and certified reference materials (GBW08608).

Authors

Institutions

Publication Details

Journal
Microchemical Journal
Published
2025-04-18
DOI
https://doi.org/10.1016/j.microc.2025.113695
Citations
6
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
4.51

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultra-sensitive determination of Zn, Cd, Ni, Cu, and Pb in high salt matrix water samples using solid phase extraction coupled with solution cathode glow discharge atomic emission spectrometry

Jihui Shi, Zheng Wang, Qing Li, Meng Gao
6 citations
Microchemical Journal
Analytical chemistry methods development
4.51
article

Ultra-sensitive determination of Zn, Cd, Ni, Cu, and Pb in high salt matrix water samples using solid phase extraction coupled with solution cathode glow discharge atomic emission spectrometry

Jihui Shi, Zheng Wang, Qing Li, Meng Gao
article en
6 citations

Abstract

• Multiple heavy metals were simultaneous detected using SCGD-AES coupled with SPE . • The tolerance of SPE-SCGD-AES against the salt matrix could reach up to 10000 mg/L. • The DLs of Zn, Cd, Ni, Cu, and Pb were 1, 0.6, 2, 0.6, and 6 μg/L. Herein, we developed a highly sensitive method based on solution cathode glow discharge atomic emission spectrometry (SCGD-AES) coupled with solid-phase extraction (SPE) for the determination of Zn, Cd, Ni, Cu, and Pb in high salt matrix water samples. The trace metals were collected from 100 mL water which was adjusted the pH to 4–10 (this step was unnecessary for most environmental water samples due to their inherent pH compatibility) using a column (i.d. = 6.6 mm) of a chelating resin (bed height = 7.2 cm) and eluted with 5 mL 1 M HNO 3 at a flow rate of 3 mL/min. At the same time, the pH of the eluate would be adjust from 0 to 0.9 (a suitable acidity for SCGD) by the resin column. Then the heavy metals in elute were detected by SCGD with constant current mode. When 100 mL sample water was enriched, the detection limits of Zn, Cd, Ni, Cu, and Pb were 1, 0.6, 2, 0.6, and 6 μg/ L which were improved by almost 20 times. And the tolerance of SCGD for Cd, Cu, Ni, Pb, and Zn detection against the salt matrix (exemplified by Na) could reach up to 10000 mg/L. The method’s accuracy and practicality were validated through successful application to environmental water samples, high salt matrix simulated water and certified reference materials (GBW08608).

Microchemical JournalVol. 213
Chinese Academy of Sciences (CN), Shanghai Institute of Ceramics (CN), University of Chinese Academy of Sciences (CN)
National Natural Science Foundation of China, Science and Technology Innovation Plan Of Shanghai Science and Technology Commission
Clean water and sanitation
Openalex Percentile: Top 5%
Analytical chemistry methods development
4.51
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.