Nanoscale evaluation of the dynamic interface and corrosion resistance of the chemically generated oxide film on dental vitallium alloy in simulated physiological solution

Various biomaterials including Vitallium alloys are frequently utilized in medical applications, in particular as dental materials. A fundamental prerequisite for their application is their biocompatibility, mechanical stability , and corrosion resistance in the oral cavity. Herein, the corrosion resistance of a ternary CoCrMo alloy , namely Vitallium, was investigated in a simulated physiological medium, 0.9 % NaCl saline solution , at body temperature over various immersion times. The corrosion behavior and surface passivation were evaluated using open circuit measurement, potentiodynamic polarization, electrochemical impedance spectroscopy (EIS), Mott–Schottky analysis along with X-ray diffraction (XRD), scanning electron (SEM) and atomic force (AFM) microscopy. To assess the stability of the created passive film, the study was performed over 7 days of immersion in the saline solution. The electrochemical polarization tests revealed a decrease in the corrosion current along with an increase in the corrosion resistance after 168 h. Furthermore, EIS showed an improvement in the protective properties of the passive film with prolonged exposure. This was confirmed by ICP-AES analysis. Additionally, this chemically generated passive film exhibited n-p type semiconductor characteristics, with increasing thickness and fewer defects over the immersion time, making it more protective. XRD analysis revealed only a γ-phase with a face-centered cubic structure. Importantly, the microstructure and roughness parameters of the alloy surface were evaluated with prolonged exposure to the corrosive medium at the nanoscale using SEM-EDX and AFM . Results elucidated that the origin of the corrosion resistance of Vitallium stems mainly from the formation of a passive layer.

Authors

Institutions

Publication Details

Journal
Surfaces and Interfaces
Published
2025-04-18
DOI
https://doi.org/10.1016/j.surfin.2025.106517
Citations
6
Primary Topic
Corrosion Behavior and Inhibition
Type
article
Field-Weighted Citation Impact
3.11
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nanoscale evaluation of the dynamic interface and corrosion resistance of the chemically generated oxide film on dental vitallium alloy in simulated physiological solution

Anton José Garcia, M. Boudalia, Hatem M.A. Amin, Abdelkbir Bellaouchou et al.
6 citations
Surfaces and Interfaces
Corrosion Behavior and Inhibition
3.11
article

Nanoscale evaluation of the dynamic interface and corrosion resistance of the chemically generated oxide film on dental vitallium alloy in simulated physiological solution

Anton José Garcia, M. Boudalia, Hatem M.A. Amin, Abdelkbir Bellaouchou, Manal Bassit, Mitra Bhoelai
article en
6 citations

Abstract

Various biomaterials including Vitallium alloys are frequently utilized in medical applications, in particular as dental materials. A fundamental prerequisite for their application is their biocompatibility, mechanical stability , and corrosion resistance in the oral cavity. Herein, the corrosion resistance of a ternary CoCrMo alloy , namely Vitallium, was investigated in a simulated physiological medium, 0.9 % NaCl saline solution , at body temperature over various immersion times. The corrosion behavior and surface passivation were evaluated using open circuit measurement, potentiodynamic polarization, electrochemical impedance spectroscopy (EIS), Mott–Schottky analysis along with X-ray diffraction (XRD), scanning electron (SEM) and atomic force (AFM) microscopy. To assess the stability of the created passive film, the study was performed over 7 days of immersion in the saline solution. The electrochemical polarization tests revealed a decrease in the corrosion current along with an increase in the corrosion resistance after 168 h. Furthermore, EIS showed an improvement in the protective properties of the passive film with prolonged exposure. This was confirmed by ICP-AES analysis. Additionally, this chemically generated passive film exhibited n-p type semiconductor characteristics, with increasing thickness and fewer defects over the immersion time, making it more protective. XRD analysis revealed only a γ-phase with a face-centered cubic structure. Importantly, the microstructure and roughness parameters of the alloy surface were evaluated with prolonged exposure to the corrosive medium at the nanoscale using SEM-EDX and AFM . Results elucidated that the origin of the corrosion resistance of Vitallium stems mainly from the formation of a passive layer.

Surfaces and InterfacesVol. 65
Mohammed V University (MA), Cairo University (EG), Analytisches Laboratorium (DE), Universitat Politècnica de València (ES)
Openalex Percentile: Top 8%
Corrosion Behavior and Inhibition
3.11
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.