Research on Volume Monitoring Method of Concentrated Gas in Gas Relays for Transformers

As the most important non electric protection device for transformers, gas relays play a crucial role in ensuring the safe and stable operation of transformers. With the increase of operating years, the number of defects and abnormal problems in transformers is gradually increasing. However, it is difficult to obtain the true volume of gas accumulation during light gas alarms, making it difficult to determine whether there is a false alarm. It is necessary to quickly organize substation operation and inspection personnel to carry out on-site inspections of gas volume accumulation in gas relays, analysis and testing of dissolved gases in oil, and other work. This article addresses the above issues by using a capacitive liquid level sensor to achieve detection of liquid level height with a maximum deviation of less than 0.3%. A gas volume calculation model was established based on the dense point calibration method, and on-site actual light gas volume monitoring with a maximum deviation of less than 4<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">%</sup> was successfully completed. The relevant achievements of this article have solved the problem of not being able to determine whether there is a false alarm during the light gas action of oil immersed transformers, and can provide data support for operation and maintenance personnel to grasp the real operating status of the equipment and formulate targeted operation and maintenance strategies.

Authors

Institutions

Publication Details

Published
2024-12-27
DOI
https://doi.org/10.1109/isneet64164.2024.10956043
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Volume Monitoring Method of Concentrated Gas in Gas Relays for Transformers

Mengzhao Zhu, Feng Guo, Fan Da, Xiaolei Li et al.
Non-Destructive Testing Techniques
article

Research on Volume Monitoring Method of Concentrated Gas in Gas Relays for Transformers

Mengzhao Zhu, Feng Guo, Fan Da, Xiaolei Li, Zhaoliang Gu, Fangfang Shi, Anyan Du
article en

Abstract

As the most important non electric protection device for transformers, gas relays play a crucial role in ensuring the safe and stable operation of transformers. With the increase of operating years, the number of defects and abnormal problems in transformers is gradually increasing. However, it is difficult to obtain the true volume of gas accumulation during light gas alarms, making it difficult to determine whether there is a false alarm. It is necessary to quickly organize substation operation and inspection personnel to carry out on-site inspections of gas volume accumulation in gas relays, analysis and testing of dissolved gases in oil, and other work. This article addresses the above issues by using a capacitive liquid level sensor to achieve detection of liquid level height with a maximum deviation of less than 0.3%. A gas volume calculation model was established based on the dense point calibration method, and on-site actual light gas volume monitoring with a maximum deviation of less than 4<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">%</sup> was successfully completed. The relevant achievements of this article have solved the problem of not being able to determine whether there is a false alarm during the light gas action of oil immersed transformers, and can provide data support for operation and maintenance personnel to grasp the real operating status of the equipment and formulate targeted operation and maintenance strategies.

Shanghai Electric (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 71%
Non-Destructive Testing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on Volume Monitoring Method of Concentrated Gas in Gas Relays for Transformers — Mengzhao Zhu, Feng Guo, et al. · (2024) | TGRS Research Map | TGRS