Harmonic-Constrained Three-Level Optimized Pulse Patterns for Grid-Connected Converters With $LCL$ Filters

This paper presents the computation of three-level optimized pulse patterns (OPPs) for converters connected to the grid via <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$LCL$</tex-math></inline-formula> filters. To this aim, the conventional OPP optimization problem is reformulated to account for the transfer function from the switching signal harmonics to the grid current harmonics. In addition, by incorporating constraints on grid current harmonics into the proposed OPP optimization problem, compliance with harmonic grid standards is ensured. Moreover, the restrictions that are typically imposed on multilevel switching signals, <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">i.e.</i> quarter-wave symmetry and unipolar switch positions, are relaxed in the proposed problem. This relaxation enables a reduction in current harmonic distortions within certain modulation intervals compared to conventional OPPs that do not limit grid current harmonics. The presented numerical results and real-time tests demonstrate the superior harmonic performance of the proposed harmonic-constrained relaxed OPPs, outperforming not only conventional modulation methods, such as space vector modulation (SVM), but also selective harmonic elimination (SHE) and conventional OPPs. Finally, further investigations reveal that the proposed OPPs maintain compliance with harmonic grid standards, even under variations in system parameters or when the <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$LCL$</tex-math></inline-formula> filter is downsized.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Industry Applications
Published
2025-04-17
DOI
https://doi.org/10.1109/tia.2025.3561700
Citations
4
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
2.13
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Harmonic-Constrained Three-Level Optimized Pulse Patterns for Grid-Connected Converters With $LCL$ Filters

Πέτρος Καραμανάκος, Shirin Rahmanpour, Tobias Geyer
4 citations
IEEE Transactions on Industry Applications
Power Systems and Renewable Energy
2.13
article

Harmonic-Constrained Three-Level Optimized Pulse Patterns for Grid-Connected Converters With $LCL$ Filters

Πέτρος Καραμανάκος, Shirin Rahmanpour, Tobias Geyer
article en
4 citations

Abstract

This paper presents the computation of three-level optimized pulse patterns (OPPs) for converters connected to the grid via <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$LCL$</tex-math></inline-formula> filters. To this aim, the conventional OPP optimization problem is reformulated to account for the transfer function from the switching signal harmonics to the grid current harmonics. In addition, by incorporating constraints on grid current harmonics into the proposed OPP optimization problem, compliance with harmonic grid standards is ensured. Moreover, the restrictions that are typically imposed on multilevel switching signals, <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">i.e.</i> quarter-wave symmetry and unipolar switch positions, are relaxed in the proposed problem. This relaxation enables a reduction in current harmonic distortions within certain modulation intervals compared to conventional OPPs that do not limit grid current harmonics. The presented numerical results and real-time tests demonstrate the superior harmonic performance of the proposed harmonic-constrained relaxed OPPs, outperforming not only conventional modulation methods, such as space vector modulation (SVM), but also selective harmonic elimination (SHE) and conventional OPPs. Finally, further investigations reveal that the proposed OPPs maintain compliance with harmonic grid standards, even under variations in system parameters or when the <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$LCL$</tex-math></inline-formula> filter is downsized.

IEEE Transactions on Industry ApplicationsVol. 61(5)
Tampere University (FI), ABB (Switzerland) (CH)
Affordable and clean energy
Openalex Percentile: Top 13%
Power Systems and Renewable Energy
2.13
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Harmonic-Constrained Three-Level Optimized Pulse Patterns for Grid-Connected Converters With $LCL$ Filters — Πέτρος Καραμανάκος, Shirin Rahmanpour, et al. · IEEE Transactions on Industry Applications (2025) | TGRS Research Map | TGRS