Based on the theory of free state by BushFires flow column and its threat to new power grid

In the modern new power grid, it is no longer a single voltage level, but a complex large power grid composed of AC and DC and multiple voltage levels, in which 800kV DC transmission project is the main artery of the large power grid, in the operation and management of the new large power grid, green safety vertical is its core pillar, If there is a forest fire in the transmission line corridor, it is likely to cause a tripping fault, especially for the ultra-high voltage DC transmission lines. The conductor insulation on the line will be damaged by the fire at a height of tens of meters above the ground, causing the power grid to trip. What causes this? The research group has concluded through big data analysis and multi-dimensional analysis that the “hot air column” of the forest fire is the main reason for destroying the external insulation of the ultra- high voltage DC transmission lines. The theory of the hot air column (i.e. the column theory) is extremely easy to destroy the external insulation characteristics of the power grid.

Authors

Institutions

Publication Details

Journal
E3S Web of Conferences
Published
2025-01-01
DOI
https://doi.org/10.1051/e3sconf/202562501028
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Based on the theory of free state by BushFires flow column and its threat to new power grid

Min Liu, Kaifeng Liu
E3S Web of Conferences
Power Systems and Renewable Energy
article

Based on the theory of free state by BushFires flow column and its threat to new power grid

Min Liu, Kaifeng Liu
article en

Abstract

In the modern new power grid, it is no longer a single voltage level, but a complex large power grid composed of AC and DC and multiple voltage levels, in which 800kV DC transmission project is the main artery of the large power grid, in the operation and management of the new large power grid, green safety vertical is its core pillar, If there is a forest fire in the transmission line corridor, it is likely to cause a tripping fault, especially for the ultra-high voltage DC transmission lines. The conductor insulation on the line will be damaged by the fire at a height of tens of meters above the ground, causing the power grid to trip. What causes this? The research group has concluded through big data analysis and multi-dimensional analysis that the “hot air column” of the forest fire is the main reason for destroying the external insulation of the ultra- high voltage DC transmission lines. The theory of the hot air column (i.e. the column theory) is extremely easy to destroy the external insulation characteristics of the power grid.

E3S Web of ConferencesVol. 625
Shanghai University of Electric Power (CN), China Southern Power Grid (China) (CN)
Openalex Percentile: Top 94%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines