Broad Tuning of Paper Microfluidic Properties by Covalent Surface Modification for Precise Flow Control and Sensing

In an effort to innovate on-site sensing platforms for a wide range of analytes in different matrices, microfluidic paper-based devices (μPADs) are promising candidates to bring the lab to the sample, as they allow passive, capillary-action-driven flow. Their use, however, is somewhat limited by the fact that the integration of advanced functionality and flow control is difficult. Although recent progress in this area has led to the development of on/off-valving and timing control of flow by changing the chemical and physical properties of paper, precise control over flow in paper microfluidics remains challenging. Here, we propose the use of a simple covalent modification of cellulose paper to tune its surface properties, thereby introducing a broad range of functionality and applicability. For this purpose, fatty acyl chlorides with different chain lengths were used as hydrophobic reagents to change the surface properties. The modified paper was characterized by FTIR-ATR, static water contact angle measurements, and capillary flow properties (permeability, maximum flow distance, and flow rate). The produced papers were then applied in several proof-of-concept devices to demonstrate their potential in sensing and actuating for improved on-site analysis. We demonstrate how precisely modified paper can be used for surface tension measurements and multistep valving based on its wickability for solutions of varying surface tensions, for the determination of ethanol concentration in water by monitoring the maximum flow distance in a 3D-printed device, and for the optimization of on-paper liquid-liquid extraction via fine-tuned control of capillary flow rates.

Authors

Institutions

Publication Details

Journal
ACS Applied Bio Materials
Published
2025-04-17
DOI
https://doi.org/10.1021/acsabm.4c01812
Citations
4
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
2.70

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Broad Tuning of Paper Microfluidic Properties by Covalent Surface Modification for Precise Flow Control and Sensing

Han Zuilhof, Gert IJ. Salentijn, Canan Aksoy, Ischa van Kesteren
4 citations
ACS Applied Bio Materials
Biosensors and Analytical Detection
2.70
article

Broad Tuning of Paper Microfluidic Properties by Covalent Surface Modification for Precise Flow Control and Sensing

Han Zuilhof, Gert IJ. Salentijn, Canan Aksoy, Ischa van Kesteren
article en
4 citations

Abstract

In an effort to innovate on-site sensing platforms for a wide range of analytes in different matrices, microfluidic paper-based devices (μPADs) are promising candidates to bring the lab to the sample, as they allow passive, capillary-action-driven flow. Their use, however, is somewhat limited by the fact that the integration of advanced functionality and flow control is difficult. Although recent progress in this area has led to the development of on/off-valving and timing control of flow by changing the chemical and physical properties of paper, precise control over flow in paper microfluidics remains challenging. Here, we propose the use of a simple covalent modification of cellulose paper to tune its surface properties, thereby introducing a broad range of functionality and applicability. For this purpose, fatty acyl chlorides with different chain lengths were used as hydrophobic reagents to change the surface properties. The modified paper was characterized by FTIR-ATR, static water contact angle measurements, and capillary flow properties (permeability, maximum flow distance, and flow rate). The produced papers were then applied in several proof-of-concept devices to demonstrate their potential in sensing and actuating for improved on-site analysis. We demonstrate how precisely modified paper can be used for surface tension measurements and multistep valving based on its wickability for solutions of varying surface tensions, for the determination of ethanol concentration in water by monitoring the maximum flow distance in a 3D-printed device, and for the optimization of on-paper liquid-liquid extraction via fine-tuned control of capillary flow rates.

ACS Applied Bio MaterialsVol. 8(5)
Jiaxing University (CN), Wageningen University & Research (NL)
Nederlandse Organisatie voor Wetenschappelijk Onderzoek, Wageningen University and Research
Openalex Percentile: Top 11%
Biosensors and Analytical Detection
2.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.