High‐Resolution 3D Turbo Spin‐Echo Wrist MRI at 7T Accelerated by Compressed Sensing

This study aimed to obtain high-resolution 3D isotropic turbo spin-echo (TSE) wrist MRI acquisitions at 7T, with and without fat suppression, facilitated by compressed-sensing (CS) acceleration. In 16 healthy subjects, fat-suppressed (FS) and nonfat-suppressed (NFS) TSE wrist images were obtained. The protocol consisted of a SENSE-accelerated scan, with an isotropic voxel size of 0.45 mm and acquisition time of 7 min ("SENSE45"), a 0.45-mm, 4-min CS-accelerated scan ("CS45"), and a 0.35-mm, 7-min CS-accelerated scan ("CS35"). For two subjects, additional 0.45-mm, 4-min SENSE-accelerated scans were acquired ("High-SENSE"). For the NFS scans, refocusing pulses were optimized to mitigate water-fat chemical-shift artifacts in the slab-selection direction. Anatomical visibility of wrist structures and image quality were assessed qualitatively and through musculoskeletal radiologist grading. The use of nonselective hard refocusing pulses with optimized bandwidths and a center frequency in between water and fat enabled NFS imaging. The image quality of the faster CS45 scans was lower than for SENSE45, with statistically significantly different grading in 9/16 (FS) and 2/6 (NFS) grading parameters. Nonetheless, a similar scan time reduction could not be achieved using High-SENSE. No distinct benefit of CS35 compared to SENSE45 was evident in either the FS or NFS scans. NFS CS35 exhibited enhanced bone sharpness compared to SENSE45 for some subjects, yet on a group level, the difference was not statistically significant. In conclusion, for maintained voxel size, CS presents the opportunity to achieve shorter scan times than possible with SENSE alone, but with reduced image quality. For maintained scan time, although higher resolution CS incidentally showed a promising increase in NFS bone sharpness compared to SENSE, it does not present an unequivocal advantage for 3D 7-T TSE wrist MRI at this stage. Further optimization of the acquisition and reconstruction process is recommended.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2025-04-17
DOI
https://doi.org/10.1002/nbm.70041
Citations
2
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
2.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High‐Resolution 3D Turbo Spin‐Echo Wrist MRI at 7T Accelerated by Compressed Sensing

Wietske van der Zwaag, Karin Markenroth Bloch, Mario Maas, Gustav J. Strijkers et al.
2 citations
NMR in Biomedicine
Advanced MRI Techniques and Applications
2.72
article

High‐Resolution 3D Turbo Spin‐Echo Wrist MRI at 7T Accelerated by Compressed Sensing

Wietske van der Zwaag, Karin Markenroth Bloch, Mario Maas, Gustav J. Strijkers, Matthan W.A. Caan, Aart J. Nederveen, Robert Hemke, Bobby A. Runderkamp, Mads Andersen
article en
2 citations

Abstract

This study aimed to obtain high-resolution 3D isotropic turbo spin-echo (TSE) wrist MRI acquisitions at 7T, with and without fat suppression, facilitated by compressed-sensing (CS) acceleration. In 16 healthy subjects, fat-suppressed (FS) and nonfat-suppressed (NFS) TSE wrist images were obtained. The protocol consisted of a SENSE-accelerated scan, with an isotropic voxel size of 0.45 mm and acquisition time of 7 min ("SENSE45"), a 0.45-mm, 4-min CS-accelerated scan ("CS45"), and a 0.35-mm, 7-min CS-accelerated scan ("CS35"). For two subjects, additional 0.45-mm, 4-min SENSE-accelerated scans were acquired ("High-SENSE"). For the NFS scans, refocusing pulses were optimized to mitigate water-fat chemical-shift artifacts in the slab-selection direction. Anatomical visibility of wrist structures and image quality were assessed qualitatively and through musculoskeletal radiologist grading. The use of nonselective hard refocusing pulses with optimized bandwidths and a center frequency in between water and fat enabled NFS imaging. The image quality of the faster CS45 scans was lower than for SENSE45, with statistically significantly different grading in 9/16 (FS) and 2/6 (NFS) grading parameters. Nonetheless, a similar scan time reduction could not be achieved using High-SENSE. No distinct benefit of CS35 compared to SENSE45 was evident in either the FS or NFS scans. NFS CS35 exhibited enhanced bone sharpness compared to SENSE45 for some subjects, yet on a group level, the difference was not statistically significant. In conclusion, for maintained voxel size, CS presents the opportunity to achieve shorter scan times than possible with SENSE alone, but with reduced image quality. For maintained scan time, although higher resolution CS incidentally showed a promising increase in NFS bone sharpness compared to SENSE, it does not present an unequivocal advantage for 3D 7-T TSE wrist MRI at this stage. Further optimization of the acquisition and reconstruction process is recommended.

NMR in BiomedicineVol. 38(6)
Netherlands Institute for Neuroscience (NL), Lund University (SE), Spinoza Centre for Neuroimaging (NL), University of Amsterdam (NL)
Clean water and sanitation
Openalex Percentile: Top 11%
Advanced MRI Techniques and Applications
2.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.