Detection and data analysis of bearing cage perpendicularity of pressed slope surface generatrix

Abstract In this paper, the detection method of bearing cage perpendicularity of pressed slope surface generatrix is studied. The theory of the verticality of the slope prime line is analyzed, and a corresponding experimental detection system is designed. A laser displacement sensor is used to monitor the change of distance between the roller and the sensor in real-time to indirectly reflect the verticality of the slope prime line. In the experiment, the Noise Reduction technology and the detection curve extraction method based on the Parabola principle are adopted. Finally, the average value of the verticality of the pressure slope prime line and its error range are obtained. The experimental results show that the proposed detection method has an accuracy of micron level and an error of less than 0.1737°.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-04-01
DOI
https://doi.org/10.1088/1742-6596/2996/1/012025
Primary Topic
Advanced Measurement and Metrology Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection and data analysis of bearing cage perpendicularity of pressed slope surface generatrix

Yanbing Zhou, Jinwei Qiao, Xiuli Jiang, Shihao Li et al.
Journal of Physics Conference Series
Advanced Measurement and Metrology Techniques
article

Detection and data analysis of bearing cage perpendicularity of pressed slope surface generatrix

Yanbing Zhou, Jinwei Qiao, Xiuli Jiang, Shihao Li, Jianghai Lin, Shiyu Zheng, P. P. Zhao
article en

Abstract

Abstract In this paper, the detection method of bearing cage perpendicularity of pressed slope surface generatrix is studied. The theory of the verticality of the slope prime line is analyzed, and a corresponding experimental detection system is designed. A laser displacement sensor is used to monitor the change of distance between the roller and the sensor in real-time to indirectly reflect the verticality of the slope prime line. In the experiment, the Noise Reduction technology and the detection curve extraction method based on the Parabola principle are adopted. Finally, the average value of the verticality of the pressure slope prime line and its error range are obtained. The experimental results show that the proposed detection method has an accuracy of micron level and an error of less than 0.1737°.

Journal of Physics Conference SeriesVol. 2996(1)
Qilu University of Technology (CN), Liaocheng University (CN), Shandong Academy of Sciences (CN), Rongcheng City People's Hospital (CN)
Openalex Percentile: Top 93%
Advanced Measurement and Metrology Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.