Abstract The electromagnetic environment of power systems is complex, and under the influence of the principle of minimum magnetic current, the simulation effect of reducing the cutoff frequency of frequency-doubled signals is compromised, leading to inconsistent resonance conditions and low accuracy in voltage detection results. In response to these issues, a detection algorithm for the induced voltage in the primary winding of a transformer is proposed. By applying a resonance boosting algorithm, a withstand voltage test method is employed where a 3x frequency test voltage is directly applied to the primary winding of the transformer, and the test voltage is measured again directly using a capacitive voltage divider. Test reactors, excitation transformers, capacitive voltage dividers, and variable frequency power supply devices are selected to ensure that the test circuit meets the resonance condition at the 3x frequency. Field test results demonstrate that the test voltage frequency obtained by the proposed algorithm meets the requirements for a 3x frequency test voltage, and the detection results of the induced voltage in the primary winding are more accurate. This algorithm is well-suited for frequency-doubled withstand voltage tests of transformers rated at 500kV and above. It is of great significance for ensuring the safe and stable operation of power systems.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-04-01
DOI
https://doi.org/10.1088/1742-6596/2996/1/012017
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection algorithm for induced voltage in primary winding of transformer

Gang Wei, Yueqiang Zhao, Zeqiao Ma, Mingyu Cao
Journal of Physics Conference Series
Power Transformer Diagnostics and Insulation
article

Detection algorithm for induced voltage in primary winding of transformer

Gang Wei, Yueqiang Zhao, Zeqiao Ma, Mingyu Cao
article en

Abstract

Abstract The electromagnetic environment of power systems is complex, and under the influence of the principle of minimum magnetic current, the simulation effect of reducing the cutoff frequency of frequency-doubled signals is compromised, leading to inconsistent resonance conditions and low accuracy in voltage detection results. In response to these issues, a detection algorithm for the induced voltage in the primary winding of a transformer is proposed. By applying a resonance boosting algorithm, a withstand voltage test method is employed where a 3x frequency test voltage is directly applied to the primary winding of the transformer, and the test voltage is measured again directly using a capacitive voltage divider. Test reactors, excitation transformers, capacitive voltage dividers, and variable frequency power supply devices are selected to ensure that the test circuit meets the resonance condition at the 3x frequency. Field test results demonstrate that the test voltage frequency obtained by the proposed algorithm meets the requirements for a 3x frequency test voltage, and the detection results of the induced voltage in the primary winding are more accurate. This algorithm is well-suited for frequency-doubled withstand voltage tests of transformers rated at 500kV and above. It is of great significance for ensuring the safe and stable operation of power systems.

Journal of Physics Conference SeriesVol. 2996(1)
PowerChina (China) (CN)
Openalex Percentile: Top 94%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Detection algorithm for induced voltage in primary winding of transformer — Gang Wei, Yueqiang Zhao, et al. · Journal of Physics Conference Series (2025) | TGRS Research Map | TGRS