Functional Polytetrafluoroethylene Membrane-Assisted Purge and Trap Detection of Residual Solvents in Pharmaceutical Formulations Using a Needle-Type Extraction Device

This study proposes a novel analytical method for the sensitive and rapid detection of residual solvents in pharmaceutical formulations. In this method, a powdered tablet is dissolved and treated via purge and trap extraction using a functional polytetrafluoroethylene (PTFE) membrane and a needle-type extraction device. Specifically, the powdered sample and sodium chloride were added to 5 mL of pure water in a glass solid-phase extraction cartridge, followed by stirring until the dissolution of the solids. Subsequently, 100 mL of headspace gas was collected using a needle-type extraction device packed with Carbopack X and carbon molecular sieve as adsorbents. During the active sampling, a purging gas was introduced into the solution from the bottom of the cartridge through a functional PTFE membrane, which retained the solution while allowing the purging gas to pass. The typical sample collection time was 10 min. Following the sample collection, the extraction needle was directly inserted into a heated gas chromatographic injection port, and the extracted analytes were thermally desorbed and analyzed using a flame ionization detector. The limits of detections for benzene, carbon tetrachloride, 1,2-dichloroethane, 1,1-dichloroethylene, and 1,1,1-trichloroethane (Class 1 compounds) were 0.005, 0.5, 0.005, 0.01, and 0.01 w/w ppm, respectively. The recovery of the target compounds did not depend on the formulation, and the proposed method demonstrated sufficient recovery and sensitivity for hydrophobic analytes, whereby allowing simple and rapid sample preparation.

Authors

Institutions

Publication Details

Journal
Chromatography
Published
2025-04-17
DOI
https://doi.org/10.15583/jpchrom.2025.002
Citations
2
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
1.51

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Functional Polytetrafluoroethylene Membrane-Assisted Purge and Trap Detection of Residual Solvents in Pharmaceutical Formulations Using a Needle-Type Extraction Device

Yoshihiro Saito, Ikuo Ueta, Ryosuke Kikuchi, Koki NAKAGAMI et al.
2 citations
Chromatography
Analytical Chemistry and Chromatography
1.51
article

Functional Polytetrafluoroethylene Membrane-Assisted Purge and Trap Detection of Residual Solvents in Pharmaceutical Formulations Using a Needle-Type Extraction Device

Yoshihiro Saito, Ikuo Ueta, Ryosuke Kikuchi, Koki NAKAGAMI, Daisuke Kondo, Suguru MASUDA
article en
2 citations

Abstract

This study proposes a novel analytical method for the sensitive and rapid detection of residual solvents in pharmaceutical formulations. In this method, a powdered tablet is dissolved and treated via purge and trap extraction using a functional polytetrafluoroethylene (PTFE) membrane and a needle-type extraction device. Specifically, the powdered sample and sodium chloride were added to 5 mL of pure water in a glass solid-phase extraction cartridge, followed by stirring until the dissolution of the solids. Subsequently, 100 mL of headspace gas was collected using a needle-type extraction device packed with Carbopack X and carbon molecular sieve as adsorbents. During the active sampling, a purging gas was introduced into the solution from the bottom of the cartridge through a functional PTFE membrane, which retained the solution while allowing the purging gas to pass. The typical sample collection time was 10 min. Following the sample collection, the extraction needle was directly inserted into a heated gas chromatographic injection port, and the extracted analytes were thermally desorbed and analyzed using a flame ionization detector. The limits of detections for benzene, carbon tetrachloride, 1,2-dichloroethane, 1,1-dichloroethylene, and 1,1,1-trichloroethane (Class 1 compounds) were 0.005, 0.5, 0.005, 0.01, and 0.01 w/w ppm, respectively. The recovery of the target compounds did not depend on the formulation, and the proposed method demonstrated sufficient recovery and sensitivity for hydrophobic analytes, whereby allowing simple and rapid sample preparation.

ChromatographyVol. 46(2)
Toyohashi University of Technology (JP), University of Yamanashi Hospital (JP), University of Yamanashi (JP)
Japan Society for the Promotion of Science
Openalex Percentile: Top 20%
Analytical Chemistry and Chromatography
1.51
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.