Process Engineering Optimization and Validation of Measurement Parameters at The Biomass Drying Test Stand

This research is motivated by the need for the efficiency of the biomass solid fuel drying process in existing dryer installations. This study aims to optimize the insulation on the primary and secondary sides of the spiral heat exchanger and validate the electrical power on the heater register and the heat flow measured by the system. The approach used was the application of a mixture of 25 ml ISO PUR K 760 and 100 ml ISO-PUR K760 Härter (ISO-ELEKTRA Elektrochemische Fabrik GmbH) and the comparison of thermal and electrical power results calculated using temperature difference data between the inlet and outlet of the heater register without readings in a PC regulator. Experiments were conducted with constant parameters, i.e. target temperature 50°C, fan power level 7, and compressor electricity consumption 541 W. This study proves that after sealing the spiral heat exchanger, there is an increase in energy consumption efficiency. In addition, the approach based on temperature difference in calculating heat power can improve the accuracy in observing energy in the biomass drying system.

Authors

Institutions

Publication Details

Journal
Jurnal Teknologi Terapan G-Tech
Published
2025-04-12
DOI
https://doi.org/10.70609/gtech.v9i2.6818
Primary Topic
Manufacturing Process and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Process Engineering Optimization and Validation of Measurement Parameters at The Biomass Drying Test Stand

Agustinus Agustinus, Joni Joni, Anastasia Sri Werdhani, Samuel Parlindungan Siregar et al.
Jurnal Teknologi Terapan G-Tech
Manufacturing Process and Optimization
article

Process Engineering Optimization and Validation of Measurement Parameters at The Biomass Drying Test Stand

Agustinus Agustinus, Joni Joni, Anastasia Sri Werdhani, Samuel Parlindungan Siregar, Mickael Ruben Kaiway, Agustinus Giai, Syilius Rantepulung
article en

Abstract

This research is motivated by the need for the efficiency of the biomass solid fuel drying process in existing dryer installations. This study aims to optimize the insulation on the primary and secondary sides of the spiral heat exchanger and validate the electrical power on the heater register and the heat flow measured by the system. The approach used was the application of a mixture of 25 ml ISO PUR K 760 and 100 ml ISO-PUR K760 Härter (ISO-ELEKTRA Elektrochemische Fabrik GmbH) and the comparison of thermal and electrical power results calculated using temperature difference data between the inlet and outlet of the heater register without readings in a PC regulator. Experiments were conducted with constant parameters, i.e. target temperature 50°C, fan power level 7, and compressor electricity consumption 541 W. This study proves that after sealing the spiral heat exchanger, there is an increase in energy consumption efficiency. In addition, the approach based on temperature difference in calculating heat power can improve the accuracy in observing energy in the biomass drying system.

Jurnal Teknologi Terapan G-TechVol. 9(2)
Cenderawasih University (ID)
Openalex Percentile: Top 90%
Manufacturing Process and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.