Review on high-temperature superconducting magnet technology for its development in ultra-high-field MRI

Abstract MR researchers pursue higher and higher B 0 fields for new discoveries in medical sciences. High-temperature superconducting (HTS) magnets exhibit potential advantages of compactness, cryogen-free operation and ultra-high field (UHF) performance when utilized as the key component in UHF-MRI systems. Intensive research on HTS magnets have been conducted in recent years. This review reports on up-to-date HTS magnet techniques, analyzing their challenges and solutions for potential application in UHF-MRI magnets. Two commercial HTS tapes of Bi2223 and REBCO are discussed, highlighting their applications in MRI/NMR magnets and other UHF magnets. Technical problems, especially for the REBCO magnet with the screening current effect, small radial tensile strength, tape performance uncertainty, etc are introduced alongside mitigation strategies. The no-insulation technique and its implications for quench transient behavior are also explored. Given the absence of an UHF-MRI magnet with the HTS technology in the world at the time of formulating this review, the achievements of some other large-scale UHF-magnet projects with the HTS technology are investigated. Sequential engineering phases with two prototype magnets are thus proposed for a developing roadmap of the HTS UHF-MRI magnet. The detailed development cost is estimated within a decent price range. Besides, for the development of a first-in-kind UHF-MRI system with an HTS magnet, the insight is provided that the UHF-magnet development is a make-or-break component and due a primary and independent project to ensure its successful integration to the entire UHF-MRI system. Beyond the introduction and the conclusion, this review is structured with eight thematic sections. The beginning of each section/sub-section is tailored to the UHF-MR researchers with an introduction to basic magnet knowledge, and the remaining and major part is presented with in-depth technical analyses for the UHF-magnet specialists.

Authors

Institutions

Publication Details

Journal
Superconductor Science and Technology
Published
2025-04-17
DOI
https://doi.org/10.1088/1361-6668/adce3f
Citations
4
Primary Topic
Superconducting Materials and Applications
Type
article
Field-Weighted Citation Impact
2.70
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Review on high-temperature superconducting magnet technology for its development in ultra-high-field MRI

Yi Li
4 citations
Superconductor Science and Technology
Superconducting Materials and Applications
2.70
article

Review on high-temperature superconducting magnet technology for its development in ultra-high-field MRI

Yi Li
article en
4 citations

Abstract

Abstract MR researchers pursue higher and higher B 0 fields for new discoveries in medical sciences. High-temperature superconducting (HTS) magnets exhibit potential advantages of compactness, cryogen-free operation and ultra-high field (UHF) performance when utilized as the key component in UHF-MRI systems. Intensive research on HTS magnets have been conducted in recent years. This review reports on up-to-date HTS magnet techniques, analyzing their challenges and solutions for potential application in UHF-MRI magnets. Two commercial HTS tapes of Bi2223 and REBCO are discussed, highlighting their applications in MRI/NMR magnets and other UHF magnets. Technical problems, especially for the REBCO magnet with the screening current effect, small radial tensile strength, tape performance uncertainty, etc are introduced alongside mitigation strategies. The no-insulation technique and its implications for quench transient behavior are also explored. Given the absence of an UHF-MRI magnet with the HTS technology in the world at the time of formulating this review, the achievements of some other large-scale UHF-magnet projects with the HTS technology are investigated. Sequential engineering phases with two prototype magnets are thus proposed for a developing roadmap of the HTS UHF-MRI magnet. The detailed development cost is estimated within a decent price range. Besides, for the development of a first-in-kind UHF-MRI system with an HTS magnet, the insight is provided that the UHF-magnet development is a make-or-break component and due a primary and independent project to ensure its successful integration to the entire UHF-MRI system. Beyond the introduction and the conclusion, this review is structured with eight thematic sections. The beginning of each section/sub-section is tailored to the UHF-MR researchers with an introduction to basic magnet knowledge, and the remaining and major part is presented with in-depth technical analyses for the UHF-magnet specialists.

Superconductor Science and TechnologyVol. 38(6)
Peking University Shenzhen Hospital (CN), University Hospital Magdeburg (DE)
Openalex Percentile: Top 11%
Superconducting Materials and Applications
2.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.