A Numerical Investigation of the Impact of Converging/Diverging Curved Channel Configuration on the Multi‐Channel Cold Plate Hydrothermal Performance

ABSTRACT With the advancement of modern electronics and the increase in thermal power density, heat management has become a challenge that impacts device performance. Cold plates are an effective solution in liquid cooling systems, improving heat dissipation and thermal stability. This study presents a numerical evaluation of multichannel cold plates' thermal and hydraulic performance to enhance their overall efficiency. Geometric modifications included dual ports for improved flow distribution, heat transfer, and channel structure changes, such as straight, convergent, divergent, and convergent/divergent configurations. Performance was assessed through temperature distribution, pressure drop, and cooling efficiency analysis using ANSYS Fluent 22R1 under incompressible laminar flow conditions with water mass flow rates between 0.002 and 0.006 kg/s. Compared with the performance of a conventional multi‐mini‐channel cold plate (CMMCP), the results of this study showed that the flow‐splitting effect at the outlet significantly improved thermal performance compared with a single outlet. Using one inlet and two outlets achieved higher performance for the cold plate compared with a CMMCP, reducing pressure loss by 61% and improving the Nusselt number by 14.4%. Furthermore, modifying the convergent curve of the central channel had a greater impact on the Nusselt number than modifying the divergent–convergent curve. Narrowing the central channel increased the Nusselt number by 48.71% compared with the conventional design, while also significantly reducing the plate temperature. The double‐outlet, convergent‐curved channel design performed best overall performance, achieving the highest cooling and fluid flow rates, with an overall performance of 1.81.

Authors

Institutions

Publication Details

Journal
Heat Transfer
Published
2025-04-17
DOI
https://doi.org/10.1002/htj.23355
Citations
6
Primary Topic
Lattice Boltzmann Simulation Studies
Type
article
Field-Weighted Citation Impact
8.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Numerical Investigation of the Impact of Converging/Diverging Curved Channel Configuration on the Multi‐Channel Cold Plate Hydrothermal Performance

Hayder Mohammad Jaffal, Z. Saleh
6 citations
Heat Transfer
Lattice Boltzmann Simulation Studies
8.01
article

A Numerical Investigation of the Impact of Converging/Diverging Curved Channel Configuration on the Multi‐Channel Cold Plate Hydrothermal Performance

Hayder Mohammad Jaffal, Z. Saleh
article en
6 citations

Abstract

ABSTRACT With the advancement of modern electronics and the increase in thermal power density, heat management has become a challenge that impacts device performance. Cold plates are an effective solution in liquid cooling systems, improving heat dissipation and thermal stability. This study presents a numerical evaluation of multichannel cold plates' thermal and hydraulic performance to enhance their overall efficiency. Geometric modifications included dual ports for improved flow distribution, heat transfer, and channel structure changes, such as straight, convergent, divergent, and convergent/divergent configurations. Performance was assessed through temperature distribution, pressure drop, and cooling efficiency analysis using ANSYS Fluent 22R1 under incompressible laminar flow conditions with water mass flow rates between 0.002 and 0.006 kg/s. Compared with the performance of a conventional multi‐mini‐channel cold plate (CMMCP), the results of this study showed that the flow‐splitting effect at the outlet significantly improved thermal performance compared with a single outlet. Using one inlet and two outlets achieved higher performance for the cold plate compared with a CMMCP, reducing pressure loss by 61% and improving the Nusselt number by 14.4%. Furthermore, modifying the convergent curve of the central channel had a greater impact on the Nusselt number than modifying the divergent–convergent curve. Narrowing the central channel increased the Nusselt number by 48.71% compared with the conventional design, while also significantly reducing the plate temperature. The double‐outlet, convergent‐curved channel design performed best overall performance, achieving the highest cooling and fluid flow rates, with an overall performance of 1.81.

Heat TransferVol. 54(5)
Mustansiriyah University (IQ)
Openalex Percentile: Top 2%
Lattice Boltzmann Simulation Studies
8.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Numerical Investigation of the Impact of Converging/Diverging Curved Channel Configuration on the Multi‐Channel Cold Plate Hydrothermal Performance — Hayder Mohammad Jaffal, Z. Saleh · Heat Transfer (2025) | TGRS Research Map | TGRS