Finite element analysis and clinical evaluation of cross locking external fixator configuration for distal third tibia fracture

External fixators have been used effectively in damage control orthopaedic and open fractures management of various bones. It is well known that stability of external fixators is greatly influenced by its construct. Various rules have been documented to influence the stiffness and stability of external fixators. In this study, two clinical cases treated with a novel concept of cross self-locking rods external fixation construct were being described, coupled with biomechanical analysis of its stability in comparison with other constructs by using finite element study. These novel self-locking rods configuration proven improve strength by applying the same numbers of rod and pin with the delta frame construct in clinical practice. A validated three-dimensional (3D) model of the bone from a previous study was used and external fixator were designed via computer-aided design (CAD) modelling software, Solidworks. A 1500 N load representing the axial load compression during weight bearing was applied to the tibia with the distal segment of the fracture site secured without any movement. The clinical results showed bone healing process with both cases achieving bone union within the acceptable time. The results of the finite element study shows that the double cross self-locking rods construct had better stability since it showed optimum magnitude in relative micromotion (0.18 mm), lowest stress at the fracture site (189 MPa), displacement of fixator (13.4 mm), and stress at the fixator (687 MPa). In conclusion, double cross self-locking design could provide optimum stability of the external fixator construct by providing better stress distribution at the bone and external fixator, minimize displacement and micromotion at fracture fragments.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-04-17
DOI
https://doi.org/10.1038/s41598-025-97090-4
Citations
3
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
4.06

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Finite element analysis and clinical evaluation of cross locking external fixator configuration for distal third tibia fracture

Muhammad Hanif Ramlee, Abdul Hadi Abdul Wahab, Mohammed Rafiq Abdul Kadir, Nik Nur Ain Azrin Abdullah et al.
3 citations
Scientific Reports
Bone fractures and treatments
4.06
article

Finite element analysis and clinical evaluation of cross locking external fixator configuration for distal third tibia fracture

Muhammad Hanif Ramlee, Abdul Hadi Abdul Wahab, Mohammed Rafiq Abdul Kadir, Nik Nur Ain Azrin Abdullah, Abdul Muttalib Abdul Wahid, Muhammad Imam Ammarullah, Ng Bing Wui
article en
3 citations

Abstract

External fixators have been used effectively in damage control orthopaedic and open fractures management of various bones. It is well known that stability of external fixators is greatly influenced by its construct. Various rules have been documented to influence the stiffness and stability of external fixators. In this study, two clinical cases treated with a novel concept of cross self-locking rods external fixation construct were being described, coupled with biomechanical analysis of its stability in comparison with other constructs by using finite element study. These novel self-locking rods configuration proven improve strength by applying the same numbers of rod and pin with the delta frame construct in clinical practice. A validated three-dimensional (3D) model of the bone from a previous study was used and external fixator were designed via computer-aided design (CAD) modelling software, Solidworks. A 1500 N load representing the axial load compression during weight bearing was applied to the tibia with the distal segment of the fracture site secured without any movement. The clinical results showed bone healing process with both cases achieving bone union within the acceptable time. The results of the finite element study shows that the double cross self-locking rods construct had better stability since it showed optimum magnitude in relative micromotion (0.18 mm), lowest stress at the fracture site (189 MPa), displacement of fixator (13.4 mm), and stress at the fixator (687 MPa). In conclusion, double cross self-locking design could provide optimum stability of the external fixator construct by providing better stress distribution at the bone and external fixator, minimize displacement and micromotion at fracture fragments.

Scientific ReportsVol. 15(1)
Ministry of Health (MY), Diponegoro University (ID), University Kebangsaan Malaysia Medical Centre (MY), University of Malaya (MY), University of Technology Malaysia (MY), Tunku Abdul Rahman University of Management and Technology (MY)
Strong, Universiti Teknologi Malaysia, Universitas Sriwijaya
Openalex Percentile: Top 7%
Bone fractures and treatments
4.06
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.