SENSITIVITY OF GRAPHENE OXIDE COATED TAPERED NO-CORE FIBRE SENSOR FOR URIC ACID DETECTION

This paper analyses the development, progress, and evaluation of a sensor system, which mainly consists of tapered no-core fibre (TNCF) for detecting uric acid (UA). To augment the capability of TNCF diameter, different powers of CO2 laser were used for creating the optical-based refractive index sensor. This action will allow for better interaction with the surrounding samples, improving the sensitivity. The sensing region was fixed to improve the sensitivity with a coating of graphene oxide (GO) solution. Experimental findings showed that the TNCF-GO sensor exhibited a higher sensitivity value at 0.00782 ± 0.00049 nm/µM, while NCF-GO sensor sensitivity only at 0.00447 ± 0.00019 nm/µM and NCF sensor sensitivity only at 0.00387 ± 0.00027 nm/µM. The TNCF-GO sensor demonstrated better performance compared to the others. This research improves the development of a susceptible and effective sensor for UA detection, especially in biomedical health diagnostics.

Authors

Institutions

Publication Details

Journal
Journal of Engineering and Technology (JET)
Published
2024-12-31
DOI
https://doi.org/10.54554/jet.2024.15.2.014
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SENSITIVITY OF GRAPHENE OXIDE COATED TAPERED NO-CORE FIBRE SENSOR FOR URIC ACID DETECTION

Muhammad Ilham Ahmad Zaini, Ahmad Fakhrurrazi Ahmad Noorden, Suzairi Daud
Journal of Engineering and Technology (JET)
Gas Sensing Nanomaterials and Sensors
article

SENSITIVITY OF GRAPHENE OXIDE COATED TAPERED NO-CORE FIBRE SENSOR FOR URIC ACID DETECTION

Muhammad Ilham Ahmad Zaini, Ahmad Fakhrurrazi Ahmad Noorden, Suzairi Daud
article en

Abstract

This paper analyses the development, progress, and evaluation of a sensor system, which mainly consists of tapered no-core fibre (TNCF) for detecting uric acid (UA). To augment the capability of TNCF diameter, different powers of CO2 laser were used for creating the optical-based refractive index sensor. This action will allow for better interaction with the surrounding samples, improving the sensitivity. The sensing region was fixed to improve the sensitivity with a coating of graphene oxide (GO) solution. Experimental findings showed that the TNCF-GO sensor exhibited a higher sensitivity value at 0.00782 ± 0.00049 nm/µM, while NCF-GO sensor sensitivity only at 0.00447 ± 0.00019 nm/µM and NCF sensor sensitivity only at 0.00387 ± 0.00027 nm/µM. The TNCF-GO sensor demonstrated better performance compared to the others. This research improves the development of a susceptible and effective sensor for UA detection, especially in biomedical health diagnostics.

Journal of Engineering and Technology (JET)Vol. 15(2)
International Islamic University Malaysia (MY), University of Technology Malaysia (MY)
Openalex Percentile: Top 73%
Gas Sensing Nanomaterials and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

SENSITIVITY OF GRAPHENE OXIDE COATED TAPERED NO-CORE FIBRE SENSOR FOR URIC ACID DETECTION — Muhammad Ilham Ahmad Zaini, Ahmad Fakhrurrazi Ahmad Noorden, et al. · Journal of Engineering and Technology (JET) (2024) | TGRS Research Map | TGRS