Accre 8 emerging point of care CLIA system for vitamin B12 assessment compared with three established assays

Accurate Vitamin B12 (Vit B12) quantification is essential for diagnosing deficiencies linked to neurological and hematological disorders. The Accre 8 Point-of-Care (POC) Chemiluminescent Immunoassay (CLIA) system offers a compact design, rapid single-step operation, and minimal calibration requirements. This study evaluates Accre 8's performance against established CLIA immunoassays (Abbott and Roche) and LC-MS/MS, the gold standard for Vit B12 quantification. A total of 297 serum samples, spanning deficient to sufficient Vit B12 levels, were analyzed. Accre 8 demonstrated a strong correlation with LC-MS/MS (r = 0.94, p < 0.001), with median Vit B12 levels closely aligning with LC-MS/MS (256.0 pmol/L). Accre 8 exhibited high sensitivity (96.9%) and specificity (86.7%), with Cohen's Kappa agreement (0.76). Bland-Altman analysis showed a mean bias of - 18.5%, while Passing-Bablok regression indicated proportional bias at higher concentrations (slope = 1.44). ROC analysis confirmed excellent diagnostic accuracy (AUC = 0.98). Accre 8's strong diagnostic performance, minimal calibration needs, and low sample volume requirements position it as a practical alternative to conventional CLIA systems for Vit B12 assessment, particularly in clinical and resource-limited settings. These findings support its potential integration into routine diagnostic workflows for Vit B12 deficiency screening and monitoring.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-04-17
DOI
https://doi.org/10.1038/s41598-025-97503-4
Citations
2
Primary Topic
Folate and B Vitamins Research
Type
article
Field-Weighted Citation Impact
3.34

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accre 8 emerging point of care CLIA system for vitamin B12 assessment compared with three established assays

Wanida Laiwattanapaisal, Laith Jamal Abu-Raddad, Gheyath K. Nasrallah, Dayana El Chaar et al.
2 citations
Scientific Reports
Folate and B Vitamins Research
3.34
article

Accre 8 emerging point of care CLIA system for vitamin B12 assessment compared with three established assays

Wanida Laiwattanapaisal, Laith Jamal Abu-Raddad, Gheyath K. Nasrallah, Dayana El Chaar, Parveen Banu Nizamuddin, Salma Younes, Nader Al‐Dewik, Palanee Ammaranond, Shaden Abunasser, Meng Li, Tasneem Al-Hamad, Nadin Younes, Israa M. Salameh, Farah M Trad, Pattramon Aungbamnet, Pollanat Loungjinda
article en
2 citations

Abstract

Accurate Vitamin B12 (Vit B12) quantification is essential for diagnosing deficiencies linked to neurological and hematological disorders. The Accre 8 Point-of-Care (POC) Chemiluminescent Immunoassay (CLIA) system offers a compact design, rapid single-step operation, and minimal calibration requirements. This study evaluates Accre 8's performance against established CLIA immunoassays (Abbott and Roche) and LC-MS/MS, the gold standard for Vit B12 quantification. A total of 297 serum samples, spanning deficient to sufficient Vit B12 levels, were analyzed. Accre 8 demonstrated a strong correlation with LC-MS/MS (r = 0.94, p < 0.001), with median Vit B12 levels closely aligning with LC-MS/MS (256.0 pmol/L). Accre 8 exhibited high sensitivity (96.9%) and specificity (86.7%), with Cohen's Kappa agreement (0.76). Bland-Altman analysis showed a mean bias of - 18.5%, while Passing-Bablok regression indicated proportional bias at higher concentrations (slope = 1.44). ROC analysis confirmed excellent diagnostic accuracy (AUC = 0.98). Accre 8's strong diagnostic performance, minimal calibration needs, and low sample volume requirements position it as a practical alternative to conventional CLIA systems for Vit B12 assessment, particularly in clinical and resource-limited settings. These findings support its potential integration into routine diagnostic workflows for Vit B12 deficiency screening and monitoring.

Scientific ReportsVol. 15(1)
Chulalongkorn University (TH), Guangzhou Education Bureau (CN), Hamad Medical Corporation (QA), Qatar University (QA)
Qatar University, Qatar National Library
Decent work and economic growth
Openalex Percentile: Top 9%
Folate and B Vitamins Research
3.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.