Title Pending 18993

This is an accepted article with a DOI pre-assigned that is not yet published.Ongoing discussions regarding new strategies to enhance control of Salmonella in meat and poultry include potential benefits of identifying product that exceeds various Salmonella levels. A method known as “Poisson Limit One Tube” (PiLOT) produces a positive result when a sample exceeds a threshold level of bacterial contamination. The Poisson Probability Distribution is the mathematical foundation of the PiLOT method. Thus, a PiLOT method protocol (PiLOT-95) with a 95% probability of a positive result when a chicken sample contains 1 CFU/g of Salmonella has a 50% probability of a positive result when a sample contains 0.2 CFU/g of Salmonella. The “Confidently Above Threshold” (CAT) method was developed to reduce the potential for false positive results. A CAT method protocol with an 80% probability of a positive result when a chicken sample contains 1 CFU/g of Salmonella has a 50% probability of a positive result when a sample contains 0.6 CFU/g of Salmonella. Eighty samples of the chicken component of NRTE breaded stuffed chicken products were prepared by inoculating with Salmonella levels between < 0.1 to 52.5 CFU/g. Each of the samples was assessed for the presence of Salmonella levels ≥ l.0 CFU/g with PiLOT-95 and CAT-80 protocols. For both PiLOT-95 and CAT-80 Sensitivity was 1.000 since no false positive results occurred. This result demonstrated the validity and feasibility of threshold methods for Salmonella in NRTE breaded stuffed chicken products. The CAT-80 false positive rate (FPR) of 0.225 was lower than the PiLOT-95 FPR of 0.500. PiLOT-95 and CAT-80 Specificities were 0.500 and 0.775, respectively. These results demonstrated that the CAT-80 protocol reduces the occurrence of false positive outcomes compared to the PiLOT-95 threshold protocol. CAT methods may provide an optimal approach for detecting chicken component samples with greater than or equal to 1 CFU/g Salmonella.

Institutions

Publication Details

Journal
Meat and Muscle Biology
Published
2025-04-17
DOI
https://doi.org/10.22175/mmb.18993
Primary Topic
Library Science and Information Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Title Pending 18993

Meat and Muscle Biology
Library Science and Information Systems
article

Title Pending 18993

article en

Abstract

This is an accepted article with a DOI pre-assigned that is not yet published.Ongoing discussions regarding new strategies to enhance control of Salmonella in meat and poultry include potential benefits of identifying product that exceeds various Salmonella levels. A method known as “Poisson Limit One Tube” (PiLOT) produces a positive result when a sample exceeds a threshold level of bacterial contamination. The Poisson Probability Distribution is the mathematical foundation of the PiLOT method. Thus, a PiLOT method protocol (PiLOT-95) with a 95% probability of a positive result when a chicken sample contains 1 CFU/g of Salmonella has a 50% probability of a positive result when a sample contains 0.2 CFU/g of Salmonella. The “Confidently Above Threshold” (CAT) method was developed to reduce the potential for false positive results. A CAT method protocol with an 80% probability of a positive result when a chicken sample contains 1 CFU/g of Salmonella has a 50% probability of a positive result when a sample contains 0.6 CFU/g of Salmonella. Eighty samples of the chicken component of NRTE breaded stuffed chicken products were prepared by inoculating with Salmonella levels between < 0.1 to 52.5 CFU/g. Each of the samples was assessed for the presence of Salmonella levels ≥ l.0 CFU/g with PiLOT-95 and CAT-80 protocols. For both PiLOT-95 and CAT-80 Sensitivity was 1.000 since no false positive results occurred. This result demonstrated the validity and feasibility of threshold methods for Salmonella in NRTE breaded stuffed chicken products. The CAT-80 false positive rate (FPR) of 0.225 was lower than the PiLOT-95 FPR of 0.500. PiLOT-95 and CAT-80 Specificities were 0.500 and 0.775, respectively. These results demonstrated that the CAT-80 protocol reduces the occurrence of false positive outcomes compared to the PiLOT-95 threshold protocol. CAT methods may provide an optimal approach for detecting chicken component samples with greater than or equal to 1 CFU/g Salmonella.

Meat and Muscle Biology
Agricultural Research Service (US), Roman L. Hruska U.S. Meat Animal Research Center (US)
Openalex Percentile: Top 90%
Library Science and Information Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.