Does macroscopic mass transfer affect sonochemical reaction rate in an ultrasonic bath?

In the present study, a planar laser induced fluorescence (P-LIF) measurement, reaction rate measurement, the sonochemical luminescence (SCL) observation, and the particle image velocimetry (PIV) measurement were conducted to clarify the effect of macroscopic mass transfer on sonochemical reaction rate in an ultrasonic bath. The concentration distribution was measured by the fluorescence intensity of Rhodamine 6G (Rh6G), which was illuminated by a CW-YAG laser sheet. The concentration of Rh6G decreases first in the high reaction zone measured by the SCL observation, and the resulting low-concentration zone expands to the low reaction zone through macroscopic convective mass transfer, which can be observed as solute plumes. Therefore, it is concluded that the mass transfer rate can slightly affect the chemical reaction rate due to the nonuniform concentration distribution in the early stage of sonochemical reaction. The reaction rate is slightly underestimated due to the spatial variation of the concentration in the early stage of ultrasonic degradation. The effect of macroscopic mass transfer on the sonochemical reaction rate was evaluated by first Damköhler number, which was calculated based on the flow velocity obtained by the PIV measurement and the reaction rate constant obtained by the decomposition experiment. Finally, it could be concluded that the first Damköhler number evaluates the effect of macroscopic mass transfer on the sonochemical reaction rate quantitatively and this dimensionless number can be applied to other ultrasonic bath with different condition.

Authors

Institutions

Publication Details

Journal
Ultrasonics Sonochemistry
Published
2025-04-17
DOI
https://doi.org/10.1016/j.ultsonch.2025.107361
Citations
2
Primary Topic
Ultrasound and Cavitation Phenomena
Type
article
Field-Weighted Citation Impact
1.04

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Does macroscopic mass transfer affect sonochemical reaction rate in an ultrasonic bath?

Takuya Yamamoto, Shinya Okino
2 citations
Ultrasonics Sonochemistry
Ultrasound and Cavitation Phenomena
1.04
article

Does macroscopic mass transfer affect sonochemical reaction rate in an ultrasonic bath?

Takuya Yamamoto, Shinya Okino
article en
2 citations

Abstract

In the present study, a planar laser induced fluorescence (P-LIF) measurement, reaction rate measurement, the sonochemical luminescence (SCL) observation, and the particle image velocimetry (PIV) measurement were conducted to clarify the effect of macroscopic mass transfer on sonochemical reaction rate in an ultrasonic bath. The concentration distribution was measured by the fluorescence intensity of Rhodamine 6G (Rh6G), which was illuminated by a CW-YAG laser sheet. The concentration of Rh6G decreases first in the high reaction zone measured by the SCL observation, and the resulting low-concentration zone expands to the low reaction zone through macroscopic convective mass transfer, which can be observed as solute plumes. Therefore, it is concluded that the mass transfer rate can slightly affect the chemical reaction rate due to the nonuniform concentration distribution in the early stage of sonochemical reaction. The reaction rate is slightly underestimated due to the spatial variation of the concentration in the early stage of ultrasonic degradation. The effect of macroscopic mass transfer on the sonochemical reaction rate was evaluated by first Damköhler number, which was calculated based on the flow velocity obtained by the PIV measurement and the reaction rate constant obtained by the decomposition experiment. Finally, it could be concluded that the first Damköhler number evaluates the effect of macroscopic mass transfer on the sonochemical reaction rate quantitatively and this dimensionless number can be applied to other ultrasonic bath with different condition.

Ultrasonics SonochemistryVol. 117
Osaka Prefecture University (JP), Kyoto University (JP)
Japan Science and Technology Corporation
Clean water and sanitation
Openalex Percentile: Top 26%
Ultrasound and Cavitation Phenomena
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.