Performance assessments of cascade refrigeration system with expander boosted subcooling

This study involves the application of an expander-boosted subcooling refrigeration system to improve the performance of the cascade refrigeration cycles. While previous research has focused on the role of internal heat exchangers, economizers, and ejectors, this work delves deeper into the potential of subcooling to significantly boost system efficiency. In recent years, mechanical subcooling has gained attention as a key strategy in the refrigeration and air conditioning sectors. The study proposes three system configurations: a booster in both the high- and low-temperature stages (2SB), a booster in the high-temperature stage only (HSB), and a booster in the low-temperature stage only (LSB).Performance comparisons were made between R290/R170, R717/R170, and R161/R41 refrigerant pairs, targeting both low- and ultra-low-temperature refrigeration applications. Optimum intermediate and dimensionless temperature values were identified for each refrigerant pair across varying evaporator conditions. Detailed analyses revealed that natural R290/R170 and R161/R41 offers superior COP at evaporator temperatures below −35 °C, while the performance gains were significant across all temperatures. Among the configurations, 2SB outperformed the others, with performance enhancement rates increasing as evaporator temperatures decreased. Among the refrigerant pairs analyzed in this study, R161/R41, R161/R170, and R290/R170 have demonstrated the highest performance for low-temperature and ultra-low-temperature cooling applications, respectively. The study demonstrated performance improvements of up to 20 % at low evaporator temperatures, underscoring the potential of this approach to revolutionize refrigeration efficiency.

Authors

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2025-04-17
DOI
https://doi.org/10.1016/j.csite.2025.106124
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance assessments of cascade refrigeration system with expander boosted subcooling

Önder Kaşka, Nehir Tokgöz
Case Studies in Thermal Engineering
Refrigeration and Air Conditioning Technologies
article

Performance assessments of cascade refrigeration system with expander boosted subcooling

Önder Kaşka, Nehir Tokgöz
article en

Abstract

This study involves the application of an expander-boosted subcooling refrigeration system to improve the performance of the cascade refrigeration cycles. While previous research has focused on the role of internal heat exchangers, economizers, and ejectors, this work delves deeper into the potential of subcooling to significantly boost system efficiency. In recent years, mechanical subcooling has gained attention as a key strategy in the refrigeration and air conditioning sectors. The study proposes three system configurations: a booster in both the high- and low-temperature stages (2SB), a booster in the high-temperature stage only (HSB), and a booster in the low-temperature stage only (LSB).Performance comparisons were made between R290/R170, R717/R170, and R161/R41 refrigerant pairs, targeting both low- and ultra-low-temperature refrigeration applications. Optimum intermediate and dimensionless temperature values were identified for each refrigerant pair across varying evaporator conditions. Detailed analyses revealed that natural R290/R170 and R161/R41 offers superior COP at evaporator temperatures below −35 °C, while the performance gains were significant across all temperatures. Among the configurations, 2SB outperformed the others, with performance enhancement rates increasing as evaporator temperatures decreased. Among the refrigerant pairs analyzed in this study, R161/R41, R161/R170, and R290/R170 have demonstrated the highest performance for low-temperature and ultra-low-temperature cooling applications, respectively. The study demonstrated performance improvements of up to 20 % at low evaporator temperatures, underscoring the potential of this approach to revolutionize refrigeration efficiency.

Case Studies in Thermal EngineeringVol. 71
Affordable and clean energy
Openalex Percentile: Top 93%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.